Flow inconsistency: the evil twin of column switching--hardware aspects.
MedLine Citation:
PMID:  19765715     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Solvent flow, generated by HPLC pumps is consistent and accurate. This statement, while true for single column (one dimensional) liquid chromatography applications, may not apply to column switching applications. Connection of pumps and/or columns to one flow path may cause substantial pressure changes. Immediate post valve switch pressure differences between pumps can cause backflow where the mobile phase stored at higher pressure will temporary flow into the lower pressure area. A more common side effect of column switching is flow inconsistency during pump pressurization. For the duration of pump pressurization, liquid flow through the column will be smaller than expected since the HPLC column acts like a flow restrictor.
Authors:
Eduard Rogatsky; Kara Braaten; Greg Cruikshank; Harsha Jayatillake; BingNa Zheng; Daniel T Stein
Related Documents :
18704855 - A simple way to decompress the left ventricle during venoarterial bypass.
20013905 - Pump-free and low-cost negative pressure sampling device for rapid sample loading in mce.
9326125 - Aquaflo pump vs fms 4 pump for shoulder arthroscopic surgery.
2025085 - Comparison of hemodynamics and ejection fraction during left heart bypass.
6681045 - Similar blood pressure but different outcome in rats with doc and post-doc hypertension.
12679215 - Efficacy and tolerability of eplerenone and losartan in hypertensive black and white pa...
Publication Detail:
Type:  Journal Article; Research Support, N.I.H., Extramural     Date:  2009-09-01
Journal Detail:
Title:  Journal of chromatography. A     Volume:  1216     ISSN:  1873-3778     ISO Abbreviation:  J Chromatogr A     Publication Date:  2009 Nov 
Date Detail:
Created Date:  2009-10-19     Completed Date:  2009-12-14     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9318488     Medline TA:  J Chromatogr A     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  7721-7     Citation Subset:  IM    
Affiliation:
Analytical Core Lab, Institute for Clinical and Translational Research, Albert Einstein College of Medicine of Yeshiva University, 1300 Morris Park Ave., Bronx, NY 10461, USA. eduard.rogatsky@einstein.yu.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Chromatography, High Pressure Liquid / instrumentation*
Equipment Design
Pressure
Grant Support
ID/Acronym/Agency:
UL11RR025740/RR/NCRR NIH HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Use of capillary electrophoresis with laser-induced fluorescence detection to screen and liquid chro...
Next Document:  Combining microwave-assisted extraction and liquid chromatography-ion-trap mass spectrometry for the...