| Flow capacity of gastroepiploic artery versus vein grafts for intermediate coronary artery stenosis. | |
| | |
MedLine Citation:
|
PMID: 15975353 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
BACKGROUND: Native flow competition is a significant factor affecting bypass graft patency. The objective of this study was to compare the effect of competitive flow on conduit flow dynamics in the gastroepiploic artery (GEA) and the saphenous vein graft (SVG). METHODS: In 51 patents, 23 GEAs (in-situ grafts) and 28 SVGs (aortocoronary grafts) were examined using a Doppler-tipped guidewire during coronary angiography after coronary artery bypass. Graft flow volume at rest and maximum graft flow volume during hyperemia were calculated from graft diameter and average peak velocity at rest and maximum average peak velocity induced by papaverine hydrochloride injection. Grafts were classified according to the grade of native coronary artery stenosis; group S (14 GEAs and 16 SVGs) displayed over 75% stenosis and group M (9 GEAs and 12 SVGs) exhibited over 50% up to 75% stenosis. RESULTS: In group S, no difference in flow volume was apparent between the GEA and the SVG at rest (36+/- 17 vs 42 +/- 16) and during hyperemia (78 +/- 30 vs 88 +/- 28). In group M, flow volume of the GEA was significantly lower than that of the SVG at rest (17 +/- 11 vs 38 +/- 12; p = 0.029) and during hyperemia (32 +/- 19 vs 94 +/- 46; p = 0.001). CONCLUSIONS: These data suggest that in intermediate coronary stenosis, GEA flow is compromised by native flow competition, whereas the SVG flow dynamics is maintained. However, the GEA can provide comparable flow capacity to the SVG and will achieve good surgical results when target coronary artery selection is appropriate. |
| | |
Authors:
|
Tsuyoshi Shimizu; Hiroyuki Suesada; Masaaki Cho; Shigeki Ito; Katsusuke Ikeda; Shin Ishimaru |
Related Documents
:
|
130843 - Effects of implanted doppler flowmeters on femoral vein autografts. 16828103 - Numerical modeling of simulated blood flow in idealized composite arterial coronary gra... 2695213 - Colour flow mapping in cardiology: indications and limitations. |
Publication Detail:
|
Type: Comparative Study; Journal Article |
Journal Detail:
|
Title: The Annals of thoracic surgery Volume: 80 ISSN: 1552-6259 ISO Abbreviation: Ann. Thorac. Surg. Publication Date: 2005 Jul |
Date Detail:
|
Created Date: 2005-06-24 Completed Date: 2006-08-08 Revised Date: 2006-11-15 |
Medline Journal Info:
|
Nlm Unique ID: 15030100R Medline TA: Ann Thorac Surg Country: Netherlands |
Other Details:
|
Languages: eng Pagination: 124-30 Citation Subset: AIM; IM |
Affiliation:
|
Department of Surgery II, Tokyo Medical University, Tokyo, Japan. tshimizu-cvs@umin.ac.jp |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Aged Aged, 80 and over Blood Flow Velocity Blood Vessel Prosthesis* Coronary Artery Bypass / methods* Coronary Stenosis / surgery* Female Gastroepiploic Artery / transplantation* Humans Male Middle Aged Regional Blood Flow Saphenous Vein / transplantation* |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Skeletonized gastroepiploic artery as a composite graft for total arterial revascularization.