Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.
MedLine Citation:
PMID:  10463500     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial shunt to achieve left-right balance. We have conducted numerical simulation, a mock test, and an acute animal experiment to analyze left-right heart balance during ERTAH operation. Numerical simulation was performed under conditions in which the flow of the left artificial heart was fixed at 6 L/min, the flow of the right artificial heart was varied from 4.8 to 6 L/min, and the interatrial resistance was also varied. The relationship between the interatrial shunt flow rate and the output of the left and right artificial hearts was balanced when the flow of the right artificial heart was at 5.45 L/min. In a mock test, 2 DeBakey roller pumps were connected to the left and right sides of a Donovan mock circulatory system, and an interatrial shunt was created between the inlet ports of the left and right roller pumps. The interatrial resistance of the mock system was varied from 7.7, to 4.3, and to 2.9 mm Hg x min/L when the inner diameter of the interatrial shunt was 6, 8, and 10 mm, respectively. As in the mock test, 2 roller pumps were used to bypass the right and left hearts of a goat weighing 60 kg. The flow rate of the left heart was almost constant (4.7 L/min). The flow of the right heart was approximately 4.1 L/min when the interatrial shunt flow rate was zero. A leading consideration was that the left to left shunt through the bronchial arteries in this goat was approximately 0.6 L/min. In developing the ERTAH, we considered that creating an interatrial shunt between the inlet ports of the ERTAH as well as making a difference between the chamber volumes might be effective in balancing the left-right sides of the artificial heart.
Authors:
H Wada; S Fukunaga; M Watari; H Sakai; Y Sugawara; H Ochikubo; K Imai; H Shibamura; K Orihashi; T Sueda; Y Matsuura
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Artificial organs     Volume:  23     ISSN:  0160-564X     ISO Abbreviation:  Artif Organs     Publication Date:  1999 Aug 
Date Detail:
Created Date:  1999-09-30     Completed Date:  1999-09-30     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  741-6     Citation Subset:  IM    
Affiliation:
First Department of Surgery, Hiroshima University School of Medicine, Minamiku, Japan. hwada@mcai.med.hiroshima-u.ac.jp
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Blood Flow Velocity
Cardiac Output*
Computer Simulation
Equipment Design
Goats
Heart, Artificial*
Models, Cardiovascular
Models, Structural

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Recovery from lymphocytopenia following extracorporeal circulation: simple indicator to assess surgi...
Next Document:  Peripheral vascular resistances during total left heart bypass with an oscillated blood flow.