Document Detail


First-in-man evaluation of the MOMO cobalt-chromium carbon-coated stent.
MedLine Citation:
PMID:  23339806     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Aims: Bare metal stents continue to be used for the interventional treatment of coronary artery disease. We report the clinical and angiographic results of a multicentre, single-arm evaluation of safety and feasibility of the MOMO stent (Japan Stent Technology Co., Ltd, Okayama Research Park Incubation Centre, Okayama, Japan). Methods and results: The MOMO stent is a novel thin-strut cobalt-chromium carbon-coated stent for the treatment of de novo coronary artery disease (CAD). In this prospective, non-randomised, single-arm study, 40 patients (stable and unstable angina) with single-vessel CAD were recruited into the study from three centres. Patients with lesions ≤15 mm in length and with a target vessel diameter of ≥3 mm were eligible. Angiographic follow-up was performed at six months. Quantitative coronary angiography (QCA) was used to measure acute gain and late luminal loss (LLL). Intravascular ultrasound (IVUS) was performed in 15 consecutive patients from two centres to assess the degree of neointimal proliferation within the stented segment at six-month follow-up. The MOMO stent performed well without any procedural complications with an acute procedure and technical success rate of 100%. Repeat revascularisation was performed in six patients (15%) during the six-month follow-up. Ischaemia-driven revascularisation was documented in three patients (7.5%). No myocardial infarction, stent thrombosis or cardiac death was observed. One non-cardiac death was reported secondary to lung cancer. Binary restenosis was 12.5% (n=5), and the LLL was 0.54±0.3 mm. Conclusions: This first-in-man experience demonstrates proof of concept of the safety and feasibility of the MOMO cobalt-chromium carbon-coated stent for patients with single focal de novo lesions presenting with stable and unstable CAD.
Authors:
Sujatha Kesavan; Julian W Strange; Thomas W Johnson; Silke Flohr-Roese; Andreas Baumbach
Related Documents :
23015056 - Myocardial oxygenation in dogs during reactive hyperemia.
23800086 - The association and predictive value analysis of metabolic syndrome on diastolic heart ...
24647916 - Analysis of the quantitative improvements in resting echocardiographic image sharpness ...
23489536 - Mitral apparatus assessment by delayed enhancement cmr: relative impact of infarct dist...
15464506 - Repair of myocardial infarction by epicardial deposition of bone-marrow-cell-coated mus...
23015056 - Myocardial oxygenation in dogs during reactive hyperemia.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology     Volume:  8     ISSN:  1969-6213     ISO Abbreviation:  EuroIntervention     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-01-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101251040     Medline TA:  EuroIntervention     Country:  France    
Other Details:
Languages:  eng     Pagination:  1012-8     Citation Subset:  IM    
Affiliation:
Bristol Heart Institute, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical and angiographic experience with a third-generation drug-eluting Orsiro stent in the treatm...
Next Document:  First-in-man assessment of a dedicated guidewire for transcatheter aortic valve implantation.