First experience with continuous pH measurements on fetus during delivery.
MedLine Citation:
PMID:  33607     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
First experience with continuous pH measurement is reported. It was possible to apply well calibrated electrodes to the fetal scalp in 22 cases. Of these 22 cases eight must be regarded as failures because of unstable values. Of the remaining 14 measurements, seven were of good (or acceptable) quality and seven of poor quality. The size of the electrodes and the excessive depth of penetration are probable reasons for these failures. An important condition for obtaining reliable pH values is a perpendicular position of the electrode in the fetal scalp. An indicator for correct position of the electrode appears to be the irregularity in the recording of the pH curve. Experience so far indicates that the pH electrode in its present form is not suitable for routine use.
Authors:
J M Giffei; E Saling
Related Documents :
21686347 - Non-invasive antenatal diagnosis of fetal rhesus status in an alloimmunised patient.
22105447 - Reduced pre-pregnancy proteinuria is associated with improving postnatal maternal renal...
24515907 - Limitations of embryo selection methods.
22190387 - Cerebral ventricular system in fetuses with open spina bifida at 11-13 weeks' gestation.
1152777 - Factors influencing conception in women seeking termination of pregnancy. a pilot study...
17638627 - Cul-de-sac pregnancy following in vitro fertilization and embryo transfer.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Archives of gynecology     Volume:  226     ISSN:  0170-9925     ISO Abbreviation:  Arch. Gynecol.     Publication Date:  1978 Sep 
Date Detail:
Created Date:  1979-04-25     Completed Date:  1979-04-25     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  7901051     Medline TA:  Arch Gynecol     Country:  GERMANY, WEST    
Other Details:
Languages:  eng     Pagination:  133-6     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electrodes*
Evaluation Studies as Topic
Female
Fetal Monitoring / instrumentation*
Humans
Hydrogen-Ion Concentration*
Pregnancy

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Continuous tissue pH measurement on the fetus during delivery.
Next Document:  Evaluation of continuous fetal scalp pH during labor.