Document Detail


False aneurysm due to suture loosening after aortic arch replacement.
MedLine Citation:
PMID:  12538285     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We describe a case of false aneurysm due to loosening of the anastomotic sutures 5 years after graft replacement for subacute type A aortic dissection. Leakage from the graft was controlled by tightening the suture slack indicating that suture loosening was the cause of the aneurysm. The mechanism was probably the progressive thinning of the edematous swollen aortic wall over the years causing the sutures to loosen.
Authors:
Keita Tanaka; Haruo Makuuchi; Yoshihiro Naruse; Toshiya Kobayashi; Ichiro Hayashi; Takehiko Takayama; Yusuke Namifusa
Related Documents :
304665 - Aortic dissection complicating aortocoronary saphenous vein bypass.
3339435 - Traumatic dissections of the extracranial internal carotid artery.
21301915 - Evaluation of surgical microscope-integrated intraoperative near-infrared indocyanine g...
9342985 - Qt interval changes following neck dissection. a stratified prospective study.
10986025 - Intraoperative renal duplex sonography: a valuable method for evaluating renal artery r...
1421715 - Phonoechocardiographic identification of chordal snap in hypertrophic cardiomyopathy.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Asian cardiovascular & thoracic annals     Volume:  10     ISSN:  0218-4923     ISO Abbreviation:  Asian Cardiovasc Thorac Ann     Publication Date:  2002 Dec 
Date Detail:
Created Date:  2003-01-22     Completed Date:  2003-05-14     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9503417     Medline TA:  Asian Cardiovasc Thorac Ann     Country:  Singapore    
Other Details:
Languages:  eng     Pagination:  346-8     Citation Subset:  IM    
Affiliation:
Division of Cardiovascular Surgery, Toranomon Hospital, Tokyo, Japan. kyky-tanaka@mvc.biglobe.ne.jp
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Anastomosis, Surgical / adverse effects*
Aneurysm, Dissecting / radiography,  surgery*
Aneurysm, False / etiology*,  radiography,  surgery*
Aortic Aneurysm / radiography,  surgery*
Blood Vessel Prosthesis Implantation / adverse effects
Humans
Male
Postoperative Complications*
Suture Techniques / adverse effects*
Sutures / adverse effects*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Caught in the act: impending paradoxical embolism.
Next Document:  Acquired tracheoesophageal fistula following blunt trauma to the chest.