Document Detail

Failure of impedance plethysmography to follow exercise-induced changes in limb blood flow.
MedLine Citation:
PMID:  3409623     Owner:  NLM     Status:  MEDLINE    
1. The blood flow in the forearm and the calf of six healthy volunteers was measured at rest and after exercise by impedance plethysmography using pulsatile (QZp) and venous occlusion (QZocc) methods, and by venous occlusion strain gauge plethysmography (Qsg). 2. At rest, the impedance QZp method gave values slightly higher than those of Qsg. In the forearm, the ratio QZp to Qsg was 1.26 in the supine position and 1.97 in the upright sitting position. For the calf muscle, the ratios were 1.08 in the supine position and 1.23 in the upright position. 3. Immediately after exercise, Qsg increased from resting values of approximately 2-4 ml min-1 100 ml-1 to mean values of 16-25 ml min-1 100 ml-1 in upright and supine arm or leg exercise. In contrast, the QZp values after exercise increased to only 3.1-4.6 ml min-1 100 ml-1. QZocc likewise failed to show increases in flow except in the supine leg exercise, where flow increased to 8.7 ml min-1 100 ml-1. 4. In an additional subject, it was shown that electrode position had no significant effect on the QZp blood flow measurement after exercise. 5. The failure of QZp to accurately follow the change in Qsg with exercise was probably due in part to pulsatile venous outflow. In addition, changes in microvessel packed cell volume and shear rate may influence the observed QZp. It is concluded that impedance plethysmography is not valid for estimation of limb blood flow during reactive hyperaemia after exercise.
R L Hughson
Related Documents :
22786783 - Exercise prescription patterns in patients treated with vestibular rehabilitation after...
6513773 - Vo2max responses in separate and combined arm and leg air-braked ergometer exercise.
8797413 - Relationship between lactate and ammonia thresholds in heart transplant patients.
Publication Detail:
Type:  Clinical Trial; Comparative Study; Controlled Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Clinical science (London, England : 1979)     Volume:  75     ISSN:  0143-5221     ISO Abbreviation:  Clin. Sci.     Publication Date:  1988 Jul 
Date Detail:
Created Date:  1988-10-07     Completed Date:  1988-10-07     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  7905731     Medline TA:  Clin Sci (Lond)     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  41-6     Citation Subset:  IM    
Department of Kinesiology, University of Waterloo, Ontario, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Forearm / blood supply*
Leg / blood supply*
Physical Exertion*
Plethysmography, Impedance / methods
Regional Blood Flow

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Pathogenesis of abnormal acid-base balance in the young spontaneously hypertensive rat.
Next Document:  Biochemical studies of N-methyltransferase in human and guinea-pig lung: no apparent role in the pat...