Factors affecting the sensitivity and specificity of the Heidelberg Retina Tomograph parameters to glaucomatous progression in disc photographs.
MedLine Citation:
PMID:  20346079     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Purpose:  To evaluate the factors affecting the sensitivity and specificity of the stereometric optic nerve head (ONH) parameters of the Heidelberg Retina Tomograph (HRT) to glaucomatous progression in stereoscopic ONH photographs. Methods:  The factors affecting the sensitivity and specificity of the vertical cup : disc ratio, the cup : disc area ratio, the cup volume, the rim area and a linear discriminant function to progression were analysed. These parameters were the best indicators of progression in a retrospective study of 476 eyes. The reference standard for progression was the masked evaluation of stereoscopic ONH photographs. Results:  The factors having the most significant effect on the sensitivity and specificity of the stereometric ONH parameters were the reference height difference and the mean topography standard deviation (TSD), indicating image quality. Also, the change in the TSD and age showed consistent, but variably significant, influence on all parameters tested. The sensitivity and specificity improved when there was little change in the reference height, the image quality was good and stable, and the patients were younger. The sensitivity and specificity of the vertical cup : disc ratio was improved by a large disc area and high baseline cup : disc area ratio. The rim area showed a better sensitivity and specificity for progression with a small disc area and low baseline cup : disc area ratio. Conclusion:  The factors affecting the sensitivity and specificity of the stereometric ONH parameters to glaucomatous progression in disc photographs are essentially the same as those affecting the measurement variability of the HRT.
Authors:
Ville Saarela; Aura Falck; P Juhani Airaksinen; Anja Tuulonen
Related Documents :
18040369 - Optical coherence topography based on a two-dimensional smart detector array.
19377549 - Introduction.
20389489 - Design and evaluation of an ultra-slim objective for in-vivo deep optical biopsy.
19023379 - Optimization of design and operating parameters of a space-based optical-electronic sys...
20373769 - Ionic liquids: nondestructive, nonvolatile imaging fluids for submicrometer-scale monol...
19396299 - Introduction.
23117799 - Automated segmentation algorithm for detection of changes in vaginal epithelial morphol...
15100549 - Imaging predictors of intracranial ependymomas.
24695149 - Performance evaluation of typical approximation algorithms for nonconvex ℓp-minimizat...
Publication Detail:
Type:  Journal Article     Date:  2010-03-23
Journal Detail:
Title:  Acta ophthalmologica     Volume:  90     ISSN:  1755-3768     ISO Abbreviation:  Acta Ophthalmol     Publication Date:  2012 Mar 
Date Detail:
Created Date:  2012-10-05     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101468102     Medline TA:  Acta Ophthalmol     Country:  England    
Other Details:
Languages:  eng     Pagination:  132-8     Citation Subset:  IM    
Copyright Information:
© 2010 The Authors. Acta Ophthalmologica © 2010 Acta Ophthalmologica Scandinavica Foundation.
Affiliation:
Department of Ophthalmology, University of Oulu, Oulu, Finland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Diabetic mothers and their newborn infants - rooming-in and neonatal morbidity.
Next Document:  Ultrasound biomicroscopic study of the stability of intraocular lens implants after phacoemulsificat...