Document Detail


Exploring the role of 3-dimensional simulation in surgical training: feedback from a pilot study.
MedLine Citation:
PMID:  20924292     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
STUDY DESIGN: Randomized control study assessing the efficacy of a pedicle screw insertion simulator.
OBJECTIVES: To evaluate the efficacy of an in-house developed 3-dimensional software simulation tool for teaching pedicle screw insertion, to gather feedback about the utility of the simulator, and to help identify the context and role such simulation has in surgical education.
SUMMARY OF BACKGROUND DATA: Traditional instruction for pedicle screw insertion technique consists of didactic teaching and limited hands-on training on artificial or cadaveric models before guided supervision within the operating room. Three-dimensional computer simulation can provide a valuable tool for practicing challenging surgical procedures; however, its potential lies in its effective integration into student learning.
METHODS: Surgical residents were recruited from 2 sequential years of a spine surgery course. Patient and control groups both received standard training on pedicle screw insertion. The patient group received an additional 1-hour session of training on the simulator using a CT-based 3-dimensional model of their assigned cadaver's spine. Qualitative feedback about the simulator was gathered from the trainees, fellows, and staff surgeons, and all pedicles screws physically inserted into the cadavers during the courses were evaluated through CT.
RESULTS: A total of 185 thoracic and lumbar pedicle screws were inserted by 37 trainees. Eighty-two percent of the 28 trainees who responded to the questionnaire and all fellows and staff surgeons felt the simulator to be a beneficial educational tool. However, the 1-hour training session did not yield improved performance in screw placement.
CONCLUSIONS: A 3-dimensional computer-based simulation for pedicle screw insertion was integrated into a cadaveric spine surgery instructional course. Overall, the tool was positively regarded by the trainees, fellows, and staff surgeons. However, the limited training with the simulator did not translate into widespread comfort with its operation or into improvement in physical screw placement.
Authors:
Dale J Podolsky; Allan R Martin; Cari M Whyne; Eric M Massicotte; Michael R Hardisty; Howard J Ginsberg
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of spinal disorders & techniques     Volume:  23     ISSN:  1539-2465     ISO Abbreviation:  J Spinal Disord Tech     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-12-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101140323     Medline TA:  J Spinal Disord Tech     Country:  United States    
Other Details:
Languages:  eng     Pagination:  e70-4     Citation Subset:  IM    
Affiliation:
Faculty of Medicine, Orthopaedic Biomechanics Laboratory, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada. dale.podolsky@utoronto.ca
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Moyamoya disease: a review of the disease and anesthetic management.
Next Document:  A new 3-dimensional computed tomography imaging method to diagnose extraforaminal stenosis at the lu...