Document Detail


Experimental evaluation of efficacy and healing response of everolimus-eluting stents in the familial hypercholesterolemic swine model: a comparative study of bioabsorbable versus durable polymer stent platforms.
MedLine Citation:
PMID:  24642807     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS.
METHODS: A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology.
RESULTS: At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group.
CONCLUSION: The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower levels of inflammation and slightly higher fibrin deposits compared with BMS controls.
Authors:
Armando Tellez; Paul S Seifert; Elina Donskoy; Natalia Sushkova; Douglas E Pennington; Krzysztof Milewski; Christian G Krueger; Greg L Kaluza; Michael J Eppihimer; Barbara A Huibregtse; Keith D Dawkins; Juan F Granada
Related Documents :
7348267 - The ultrastructure of the interface between a glass ceramic and bone.
18346947 - Hierarchical pore structure of calcium phosphate scaffolds by a combination of gel-cast...
20038897 - Full maxillary rehabilitation with an all-ceramic system.
23204717 - Gingival biotype - prosthodontic perspective.
1176477 - Thermal properties of cancellous bone.
20600557 - The effect of increasing sodium fluoride concentrations on erosion and attrition of ena...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-3-17
Journal Detail:
Title:  Coronary artery disease     Volume:  -     ISSN:  1473-5830     ISO Abbreviation:  Coron. Artery Dis.     Publication Date:  2014 Mar 
Date Detail:
Created Date:  2014-3-19     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9011445     Medline TA:  Coron Artery Dis     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The role of attention in a joint-action effect.
Next Document:  Heart rate recovery after exercise and its relation with neutrophil-to-lymphocyte ratio in patients ...