Experimental Evaluation of Immediate Recanalization Effect and Recanalization Efficacy of a New Thrombus Retriever for Acute Stroke Treatment In Vivo.
MedLine Citation:
PMID:  22837308     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND AND PURPOSE:Currently, several new stent retriever devices for acute stroke treatment are under development and early clinical evaluation. Preclinical testing under standardized conditions is an important first step to evaluate the technical performance and potential of these devices. The aim of this study was to evaluate the immediate recanalization effect, recanalization efficacy, thrombus-device interaction, and safety of a new stent retriever intended for thrombectomy in patients with acute stroke.MATERIAL AND METHODS:The pREset thrombectomy device (4 × 20 mm) was evaluated in 16 vessel occlusions in an established swine model. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval. Flow-restoration effect immediately after deployment and after 5-minute embedding time before retrieval, recanalization rate after retrieval, thromboembolic events, and complications were assessed. High-resolution FPCT was performed to illustrate thrombus-device interaction during the embedding time.RESULTS:Immediate flow restoration was achieved in 75% of occlusions. An increase or stable percentage of recanalizations during embedding time before retrieval was seen in 56.3%; a decrease, in 12.5%; reocclusion of a previously recanalized vessel, in 18.8%; and no recanalization effect at all, in 12.5%. Complete recanalization (TICI 3) after retrieval was achieved in 93.8%; partial recanalization (TICI 2b), in 6.2%. No distal thromboembolic events were observed. High-resolution FPCT illustrated entrapment of the thrombus between the stent struts and compression against the contralateral vessel wall, leading to partial flow restoration. During retrieval, the thrombus was retained in a straight position within the stent struts.CONCLUSIONS:In this experimental study, the pREset thrombus retriever showed a high recanalization rate in vivo. High-resolution FPCT allows detailed illustration of the thrombus-device interaction during embedding time and is advocated as an add-on tool to the animal model used in this study.
Authors:
P Mordasini; C Brekenfeld; J V Byrne; U Fischer; M Arnold; S Jung; G Schroth; J Gralla
Related Documents :
17130318 - Long-term outcome of intracardiac repair under simple deep hypothermia.
22743208 - Treatment of subacute and chronic thrombotic occlusions of lower extremity peripheral a...
24876988 - Bolus-infusion delays of alteplase during thrombolysis in acute ischaemic stroke and fu...
22592728 - Stent placement versus surgery for coarctation of the thoracic aorta.
14713588 - Conservative treatment for adolescent idiopathic scoliosis: can it reduce the incidence...
20494758 - Factors influencing corneal biomechanical changes after microincision cataract surgery ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-7-26
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  -     ISSN:  1936-959X     ISO Abbreviation:  -     Publication Date:  2012 Jul 
Date Detail:
Created Date:  2012-7-27     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Institute of Diagnostic and Interventional Neuroradiology and Department of Neurology, Inselspital, University of Bern, Bern, Switzerland; and Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Science, The John Radcliffe Hospital, University of Oxford, United Kingdom.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  High glucose inhibits the aspirin-induced activation of the nitric oxide/cGMP/cGMP-dependent protein...
Next Document:  Prediction of Carotid Plaque Characteristics Using Non-Gated MR Imaging: Correlation with Endarterec...