Expanded pediatric cardiovascular simulator for research and training.
MedLine Citation:
PMID:  20051835     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A mock circulation system has been developed to approximate key anatomic features and simulate the pressures and flows of an infant. Pulsatile flow is generated by 10 cc pulsatile ventricles (Utah infant ventricular assist device). Systemic vasculature is mimicked through the use of 3/8" ID bypass tubing with two flexible reservoirs to provide compliance. Vascular resistance, including pulmonary, aortic, and major branches, is controlled via a series of variable pinch clamps. The coronary branch has a dynamic resistor so that the majority of flow occurs during diastole. The system is instrumented to measure key pressures and flows. Right atrial pressure, left atrial pressure, pulmonary artery pressure, and mean aortic pressure are measured with high-fidelity pressure catheters (Millar Instruments, Houston, TX). Flows are measured by transit time ultrasonic flow probes (Transonic Systems, Ithaca, NY) in the pulmonary artery, aorta, coronary artery, and brachiocephalic artery along with assist device flow. The system can be tuned to create the hemodynamic values of a pediatric patient under normal or heart failure conditions. Once tuned to the desired hemodynamic conditions, the loop may be used to test the performance of various circulatory support systems including the intra-aortic balloon pump, left and right ventricular assist devices, or cardiopulmonary support systems such as extracorporeal membrane oxygenation.
Authors:
George M Pantalos; Constantine Ionan; Steven C Koenig; Kevin J Gillars; Tim Horrell; Sarina Sahetya; Jeff Colyer; Laman A Gray
Related Documents :
9212965 - Clinical evaluation of pulsatile flow mode of terumo capiox centrifugal pump.
16322725 - In vitro evaluation of the performance of korean pulsatile ecls (t-pls) using precise q...
11167565 - One month survival with the undulation pump total artificial heart in a goat.
16883115 - Hemodynamic characteristics of a mixed flow pump prototype: progress report of in vitro...
20818955 - Increased myogenic responses of resistance-sized mesenteric arteries after reduced uter...
3666995 - Coronary flow reserve and diastolic dysfunction in hypertrophic cardiomyopathy.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  56     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:    2010 Jan-Feb
Date Detail:
Created Date:  2010-01-14     Completed Date:  2010-03-09     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  67-72     Citation Subset:  IM    
Affiliation:
Departments of Surgery and Biomedical Engineering, Cardiovascular Innovation Institute, University of Louisville, Louisville, Kentucky, USA. gmpant02@louisville.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Heart-Assist Devices
Hemodynamics / physiology*
Humans
Infant
Models, Anatomic*
Models, Cardiovascular*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The adjustable systemic-pulmonary artery shunt provides precise control of flow in vivo.
Next Document:  Comparison between standard heparin and tinzaparin for haemodialysis catheter lock.