Document Detail


Examination of the temporal effect in a flow injection analysis system using multi-channel absorbance detection.
MedLine Citation:
PMID:  19371875     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In addition to the Poiseuille effect, a so-called temporal effect was proposed recently to elucidate the commonly observed tailing peak signals of flow injection analysis (FIA). A multi-channel absorbance detector was used in this study to obtain the FIA peaks on both the spatial and temporal coordinates. The temporal effect was analyzed by comparison of the profiles between the experimental and the corresponding Gaussian peaks, and by comparison of asymmetry factors between the spatial and the temporal peaks. The temporal effect appeared to be the major factor under flow rates ranging from 0.5 to 8 ml min (-1). This was despite the presence of a spatially frontal peak observed in the FIA tubing, which was found to result in a tailing peak on the temporal coordinate due to this discussed cause. In addition, the temporal effect became greater as the flow rate increased.
Authors:
Shu-Hui Lin; Kai-Chieh Chang; Yu-Chun Chen; Tiing Yu; Su-Cheng Pai
Related Documents :
18699225 - Real-time method for no(2) flow measurements.
7241425 - Home-monitoring of peak expiratory flow rate using mini-wright peak flow meter in diagn...
17272595 - Effect of long-term steroids on cough efficiency and respiratory muscle strength in pat...
1105725 - Evaluation of lung function indices for bronchodilator trials. results of a cross-over ...
1762445 - Pulsatile non-newtonian flow characteristics in a three-dimensional human carotid bifur...
8171955 - Central and regional blood flow during hyperventilation. an experimental study in the pig.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2008-11-01
Journal Detail:
Title:  Journal of chromatography. A     Volume:  1216     ISSN:  1873-3778     ISO Abbreviation:  J Chromatogr A     Publication Date:  2009 May 
Date Detail:
Created Date:  2009-05-04     Completed Date:  2009-06-23     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9318488     Medline TA:  J Chromatogr A     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  4618-24     Citation Subset:  IM    
Affiliation:
Department of Applied Chemistry, National Chiao Tung University, Hsinchu, Taiwan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Absorption
Computer Simulation
Flow Injection Analysis / methods*
Rheology
Time Factors

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Thrombin generation by intimal tissue factor contributes to thrombus formation on macrophage-rich ne...
Next Document:  Development of a rapid sanitization solution for silica-based protein A affinity adsorbents.