Document Detail


Evidenced-based comparison of aqueous shunts.
MedLine Citation:
PMID:  23287104     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE OF REVIEW: This review provides an evidence-based comparison of aqueous shunts in common use. RECENT FINDINGS: Aqueous shunts are being used with increasing frequency in the surgical management of glaucoma. Recent retrospective studies and prospective clinical trials have compared the outcomes of different shunt designs. Larger end-plate size is associated with greater intraocular pressure (IOP) reduction, but there may be an upper limit beyond which a further increase in plate surface area does not contribute beneficially to pressure control. The biocompatibility of plate material may also influence shunt efficacy. The flow restrictor of the Ahmed glaucoma valve provides an added level of safety by reducing the risk of postoperative hypotony, but this implant also appears to have a higher incidence of bleb encapsulation. SUMMARY: Several aqueous shunts are commercially available, and all have been shown to be safe and effective in lowering IOP. Studies comparing aqueous shunts have provided valuable information to assist in surgical decision-making in similar patient groups.
Authors:
Steven J Gedde; Joseph F Panarelli; Michael R Banitt; Richard K Lee
Related Documents :
23392914 - Valved shunt as a treatment for obstructive uropathy: does pressure make a difference?
20694934 - Examination of adolescents' screen time and physical fitness as independent correlates ...
4704904 - An epidemiologic study of hypertension in newfoundland.
17500894 - Irreversible shear-induced vitrification of droplets into elastic nanoemulsions by extr...
12487414 - Mobilization and entry of dnapl pools into finer sand media by cosolvents: two-dimensio...
3513664 - Three-dimensional observation of the intrahepatic lymphatics by scanning electron micro...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-2
Journal Detail:
Title:  Current opinion in ophthalmology     Volume:  -     ISSN:  1531-7021     ISO Abbreviation:  Curr Opin Ophthalmol     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9011108     Medline TA:  Curr Opin Ophthalmol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Screening for glaucoma: rationale and strategies.
Next Document:  Nanotechnology and glaucoma: little particles for a big disease.