| Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome. | |
| | |
MedLine Citation:
|
PMID: 22200390 Owner: NLM Status: In-Data-Review |
Abstract/OtherAbstract:
|
OBJECTIVE: To evaluate the reliability and validity of a body monitoring device against measures obtained from indirect calorimetry (IC) in patients with fibromyalgia syndrome (FMS) during various incremental exercise intensities. DESIGN: Cross-sectional reliability and validity study. SETTING: Testing was completed in a university exercise physiology laboratory. PARTICIPANTS: Women (N=25) with FMS, with a mean age ± SD of 48.6±8.4 years and a median symptom duration of 15 years (25th-75th percentiles, 10-23y), were recruited to the study. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Patients walked and jogged on a treadmill at 4 intensities (50m·min(-1), 0% grade [n=25]; 83.3m·min(-1), 0% grade [n=25]; 116.7m·min(-1), 0% grade [n=21]; 116.7m·min(-1), 2.5% grade [n=13]) during 2 measurement conditions, while IC and a multiple-sensor body monitor measured energy expenditure (EE). The differences between the readings (test 1 - test 2) and the SD of the differences, intraclass correlation coefficient (ICC), 95% confidence interval (CI) for the ICC, coefficient of repeatability, intrapatient SD, standard error of mean (SEM), minimal detectable change, Wilcoxon signed-rank test, and Bland-Altman graphs were used to examine reliability. The magnitude of the associations between IC and the body monitoring device, ICC, 95% CI for the ICC, paired t tests, and Bland-Altman graphs were used to examine the validity of the body monitoring device versus the IC. RESULTS: Moderate to excellent test-retest reliability was found for the 4 bouts of exercise (ICC=.73-.76). The SEM and minimal detectable change were satisfactory for the 4 bouts of exercise (.54-1.18kcal·min(-1) and 1.51-3.28kcal·min(-1), respectively). The differences mean between test and retest were lower than the SEM for the 4 bouts of exercise, varying from -.17 to .14kcal·min(-1). No significant differences were found between test and retest for any bout. The Bland-Altman plots and the coefficients of repeatability indicated that the differences between repeated tests would lie within 2 SDs in 95% of the cases for the 4 bouts of exercise. Significant associations were found between the body monitoring device and IC measurements of EE for the 4 bouts of exercise (r=.87-.99). The differences for all bouts between the 2 methods were nonsignificant, except for the second bout (P<.001). The ICCs and Bland-Altman plots of EE for the 4 bouts showed high agreement (ICCs=.84-.99) and sufficient accuracy for quantifying EE during exercise in patients with FMS. CONCLUSIONS: The body monitoring device provided a valid and reliable estimate of EE in patients with FMS during walking on horizontal and inclined surfaces in a laboratory setting across various exercise intensities. |
| | |
Authors:
|
Diego Munguía-Izquierdo; Alfredo Santalla; Alejandro Legaz-Arrese |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Archives of physical medicine and rehabilitation Volume: 93 ISSN: 1532-821X ISO Abbreviation: Arch Phys Med Rehabil Publication Date: 2012 Jan |
Date Detail:
|
Created Date: 2011-12-27 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 2985158R Medline TA: Arch Phys Med Rehabil Country: United States |
Other Details:
|
Languages: eng Pagination: 115-22 Citation Subset: AIM; IM |
Copyright Information:
|
Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved. |
Affiliation:
|
Section of Physical Education and Sports, University Pablo de Olavide, Seville, Spain. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Validation of the reintegration to normal living index for community-dwelling persons with chronic s...
Next Document: The influence of mechanically and physiologically imposed stiff-knee gait patterns on the energy cos...