OBJECTIVE: Arterial distensibility (DC) and compliance (CC) are vessel wall properties of large arteries that can be measured non-invasively with a custom made vessel wall movement detector system (VWMDS). This study investigated the reproducibility of this device in 10 volunteers. METHODS: To investigate intraobserver intrasession and intraobserver intersession variability, arterial diameter (D) and relative change in diameter during the heart cycle (delta D/D) were measured in the elastic common carotid artery, and in the muscular femoral and brachial arteries. Interobserver intrasession variability was examined in common carotid artery by two observers, while interobserver variability on the same image was assessed for common carotid and femoral arteries. Variability was expressed as the coefficient of variation. RESULTS: For common carotid artery, intraobserver intrasession variability was 7.9(SEM 1.6)% (delta D/D), 4.5(1.1)% (D), 8.3(1.3)% (DC), and 9.1(2.6)% (CC), respectively. In femoral artery it was 12.4(2.2)% (delta D/D), 2.7(0.6)% (DC), 13.4(2.2)% (DC), and 12.5(2.1)% (CC). For brachial artery it was 13.4(2.8)% (delta D/D), 2.5(0.5)% (D), 16.1(2.5)% (DC), and 15.6(2.6)% (CC). Intraobserver intersession variability was comparable to intraobserver intrasession variability for all vessels. Interobserver intrasession variability for common carotid artery was 11.3(2.6)% (delta D/D) and 8.6(1.9)% (D), but was larger for DC and CC. Interobserver variability on the same image was < 5% for common carotid and femoral arteries. CONCLUSIONS: In conclusion, the vessel wall movement detector system has a good technical reproducibility. Intraobserver intrasession and intersession variability are comparable, and are larger in muscular arteries. This might be due to a larger variation in tone of these arteries, which are under permanent neurohumoral control. Interobserver intrasession variability was larger than intraobserver variability and might be influenced by differences in observers' skill and spontaneous variation in vessel wall properties. |
| | |
Authors:
|
M J Kool; T van Merode; R S Reneman; A P Hoeks; H A Struyker Boudier; L M Van Bortel |
Related Documents
:
|
18312104 - Association between semicarbazide-sensitive amine oxidase, a regulator of the glucose t... 333934 - Structural changes within the media of coronary arteries related to intimal thickening. 20364324 - Mr image-based geometric and hemodynamic investigation of the right coronary artery wit... 12006914 - Is carotid artery intima-media thickening a reliable marker of early atherosclerosis? 17626994 - Coronary-subclavian steal: presentation and management: two case reports. 21030814 - Migration of a distal ventriculoperitoneal shunt catheter into the internal jugular vei... |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Cardiovascular research Volume: 28 ISSN: 0008-6363 ISO Abbreviation: Cardiovasc. Res. Publication Date: 1994 May |
Date Detail:
|
Created Date: 1994-08-05 Completed Date: 1994-08-05 Revised Date: 2004-11-17 |
Medline Journal Info:
|
Nlm Unique ID: 0077427 Medline TA: Cardiovasc Res Country: ENGLAND |
Other Details:
|
Languages: eng Pagination: 610-4 Citation Subset: IM |
Affiliation:
|
Cardiovascular Research Institute, University of Limburg, Maastricht, The Netherlands. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adolescent Adult Arteries / physiology* Brachial Artery / physiology, ultrasonography Carotid Artery, Common / physiology, ultrasonography Compliance Female Femoral Artery / physiology, ultrasonography Humans Male Middle Aged Observer Variation Radio Waves / diagnostic use* Reproducibility of Results Vasoconstriction / physiology* |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Effects of xanthine amine congener on hypoxic coronary resistance and venous and epicardial adenosin...
Next Document: Growth inhibition of human vascular smooth muscle cells by fenofibrate: a possible therapy for reste...