Document Detail


Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats.
MedLine Citation:
PMID:  21801057     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Objective-To compare the use of a semi-invasive vascular access port (VAP) device or noninvasive oscillometry versus invasive telemetry for blood pressure measurements in cats. Animals-6 healthy cats. Procedures-30 days before the study, all cats received an implanted telemeter and a VAP device. During normotension and experimentally induced hypertension, blood pressure was measured with the implanted devices and with noninvasive oscillometry at 4 time points. Results-Compared with invasive telemetry, VAP had a correlation coefficient from 0.8487 to 0.9972, and noninvasive oscillometry had a correlation coefficient from 0.7478 to 0.9689. Conclusions and Clinical Relevance-Use of the VAP device and noninvasive oscillometry had a high degree of correlation with invasive telemetry as the gold standard for blood pressure measurement. Use of a VAP device resulted in a slightly higher degree of correlation, compared with noninvasive oscillometry.
Authors:
Raphael J Zwijnenberg; Carlos L Del Rio; Rami M Cobb; Yukie Ueyama; William W Muir
Related Documents :
9553727 - Maintenance of arterial pressure in infant rats during moderate and extreme thermal cha...
2008097 - Continuous extracorporeal fluid removal in children with low cardiac output after cardi...
2649387 - Plasmodium berghei: malaria infection causes increased cardiac output in rats, rattus r...
1203917 - Haemodynamic effects of a new anti-arrhythmic agent, mexiletine (kö 1173) in ischaemic...
12083307 - Two-dimensional mapping of impedance magnetocardiograms.
7816527 - Changes in renal function and blood volume in the newborn lamb delivered by cesarean se...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  American journal of veterinary research     Volume:  72     ISSN:  1943-5681     ISO Abbreviation:  Am. J. Vet. Res.     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2011-08-01     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0375011     Medline TA:  Am J Vet Res     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1015-21     Citation Subset:  IM    
Affiliation:
Pfizer Animal Health Australia, 38-42 Wharf Rd, West Ryde, NSW 2114, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Development of a flow cytometric assay for detection of coated platelets in dogs and evaluation of b...
Next Document:  Evaluation of plasma activity of matrix metalloproteinase-2 and -9 in dogs with myxomatous mitral va...