Document Detail


Evaluation of a noninvasive, dual-wavelength laser-suction and massage device for the regional treatment of cellulite.
MedLine Citation:
PMID:  20517104     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Cellulite is a condition usually limited to women. The most common location for this surface irregularity is the thigh. Evaluation of treatment efficacy is difficult because of the reliance on patient satisfaction surveys and flash photography, which can "flatten" surface texture. Reproducibility of photographs is also difficult, as subtle changes in body position can affect appearance.
METHODS: Twenty women with mild to moderate cellulite of their lateral thighs were enrolled. Pretreatment and posttreatment assessment included patient weight, body mass index, percentage body fat, standard digital photographs, VECTRA three-dimensional images, and patient questionnaire. Patients received two treatments per week for 4 weeks. Treatment time was 15 minutes per thigh using the SmoothShapes device. Patients were evaluated 1, 3, and 6 months after their last treatment. To be considered improved after treatment, both thighs needed clear improvement in contour as determined by the "untextured" images obtained with the VECTRA camera system. This device depicts skin contour independent of incident lighting.
RESULTS: There were no complications. Seventeen patients had complete data for analysis. Ninety-four percent of the patients felt their cellulite was improved. VECTRA analysis showed 82 percent improvement at 1 month, 76 percent improvement at 3 months, and 76 percent improvement at 6 months. Initial cellulite irregularities and improvement were more difficult to discern using standard digital photographs. There was an average increase in patient weight, body mass index, and percentage body fat at 6 months.
CONCLUSION: The SmoothShapes device provided improvement in surface contour (cellulite) 6 months after the last treatment in the majority of the patients based on patient survey and VECTRA analysis.
Authors:
Michael I Kulick
Related Documents :
10025924 - Interferon-alpha does not improve outcome at one year in patients with diffuse cutaneou...
17328144 - Specific immunotherapy in atopic dermatitis--four-year treatment in different age and a...
11896774 - Double-blind, half-face study comparing topical vitamin c and vehicle for rejuvenation ...
20927234 - Dermoscopy in female androgenic alopecia: method standardization and diagnostic criteria.
11914254 - Primary prevention of sudden cardiac death in idiopathic dilated cardiomyopathy: the ca...
21329894 - Usefulness of tee as the primary imaging technique to guide transcatheter transapical a...
Publication Detail:
Type:  Clinical Trial; Journal Article    
Journal Detail:
Title:  Plastic and reconstructive surgery     Volume:  125     ISSN:  1529-4242     ISO Abbreviation:  Plast. Reconstr. Surg.     Publication Date:  2010 Jun 
Date Detail:
Created Date:  2010-06-02     Completed Date:  2010-06-18     Revised Date:  2014-10-13    
Medline Journal Info:
Nlm Unique ID:  1306050     Medline TA:  Plast Reconstr Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1788-96     Citation Subset:  AIM; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adipose Tissue*
Adult
Cosmetic Techniques / instrumentation*
Female
Humans
Laser Therapy / instrumentation*
Massage / instrumentation*
Middle Aged
Patient Satisfaction
Photography
Suction / instrumentation
Thigh*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Curvilinear mandibular distraction results and long-term stability effects in a group of 40 patients...
Next Document:  A 5-year assessment of safety and aesthetic results after facial soft-tissue augmentation with polya...