Document Detail


Evaluation of a new sensor-based algorithm to protect against atrial arrhythmias.
MedLine Citation:
PMID:  8945027     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The SmarTracking (ST) algorithm (Marathon 294-09, Intermedics Inc.) uses the sensor-calculated rate (SCR) to define a "variation band" for the intrinsic sinus rate. If the sinus rate exceeds the upper limit of the band, the ventricular pacing rate is limited by the ST rate (STR) and Wenckebach behavior is observed. The present study was aimed at evaluating the behavior of the ST mechanism in patients with healthy sinus node, during exercise and at rest. METHODS: Twenty-one patients (15 men; mean age 67.8 +/- 9.7 years) with normal sinus function were studied. Heart rate was recorded via the rate profile of the implanted pacemaker (Relay 294-03, Intermedics Inc.), and STR and SCR were obtained via a previously calibrated strap-on pacemaker. A 15-minute protocol was used during which subjects alternated periods of walking with periods of rest. RESULTS: The relative difference between the average STR and the average sinus rate (DST) was calculated for each phase of the protocol as well as the maximum number of patients showing inappropriate Wenckebach behavior (#W). At nominal settings, DST was always positive and did not fall below 20%. #W was maximum at rest (5) and during heavy exercise (3). By increasing the STR at rest to 95 ppm and the maximum pacing rate to 150 ppm, the #W was reduced to zero for all types of activity except during very fast walk where #W was 1. CONCLUSION: In general, there was no competition observed between the STR and the intrinsic rhythm. In some cases, the STR at rest and the maximum pacing rate had to be reprogrammed for optimal performance.
Authors:
M Delay; A Brüls; C Mounier; Y Verboven; E Somody; J Puel
Related Documents :
6209667 - Regulation of pacing rate by variations of mixed venous oxygen saturation.
3088297 - Sinus node function after selective elimination of sympathetic influences on the sinus ...
10392387 - Diagnosis of atrial undersensing in dual chamber pacemakers: impact of autodiagnostic f...
1697947 - Relationship of the effective refractory period and monophasic action potential duratio...
22022407 - Deployable laboratory response to influenza pandemic; pcr assay field trials and compar...
10536487 - Increase of soluble cytoadhesive molecules se-selectin and sicam-1 and hyperfibrinogena...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  19     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1996 Nov 
Date Detail:
Created Date:  1997-03-06     Completed Date:  1997-03-06     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1704-7     Citation Subset:  IM    
Affiliation:
Purpan Hospital, Toulouse, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Acceleration
Aged
Algorithms*
Arrhythmias, Cardiac / prevention & control*
Atrial Function
Cardiac Pacing, Artificial / methods
Electrocardiography
Electronics, Medical / instrumentation*
Equipment Design
Evaluation Studies as Topic
Female
Heart Rate
Humans
Male
Pacemaker, Artificial*
Physical Exertion / physiology
Rest / physiology
Sinoatrial Node / physiopathology
Ventricular Function
Walking / physiology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A prospective multicenter study demonstrating clinical benefit with a new accelerometer-based DDDR p...
Next Document:  Evaluation of autosensing as an automatic means of maintaining a 2:1 sensing safety margin in an imp...