Evaluation of motion management strategies based on required margins.
MedLine Citation:
PMID:  22990379     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Strategies for delivering radiation to a moving lesion each require a margin to compensate for uncertainties in treatment. These motion margins have been determined here by separating the total uncertainty into components. Probability density functions for the individual sources of uncertainty were calculated for ten motion traces obtained from the literature. Motion margins required to compensate for the center of mass motion of the clinical treatment volume were found by convolving the individual sources of uncertainty. For measurements of position at a frequency of 33 Hz, system latency was the dominant source of positional uncertainty. Averaged over the ten motion traces, the motion margin for tracking with a latency of 200 ms was 4.6 mm. Gating with a duty cycle of 33% required a mean motion margin of 3.2-3.4 mm, and tracking with a latency of 100 ms required a motion margin of 3.1 mm. Feasible reductions in the effects of the sources of uncertainty, for example by using a simple prediction algorithm to anticipate the lesion position at the end of the latency period, resulted in a mean motion margin of 1.7 mm for tracking with a latency of 100 ms, 2.4 mm for tracking with a latency of 200 ms, and 2.1-2.2 mm for the gating strategies with duty cycles of 33%. A crossover tracking latency of 150 ms was found, below which tracking strategies could take advantage of narrower motion margins than gating strategies. The methods described here provide a means to guide selection of a motion management strategy for a given patient.
Authors:
D Sawkey; M Svatos; C Zankowski
Related Documents :
1559759 - Protection by dimethylthiourea against retinal light damage in rats.
21130799 - Very-long-term and short-term chromatic adaptation: are their influences cumulative?
16635489 - Bright cyclic light rearing-mediated retinal protection against damaging light exposure...
9536349 - Absorption of white light in photoreceptors.
2833459 - Evidence in support of a photoreceptoral origin for the "light-peak substance".
23387739 - Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electrom...
23149729 - Behavioural and neurobiological implications of linear and non-linear features in laryn...
17733909 - Voyager 2 encounter with the jovian system.
21538769 - Force feedback in a piezoelectric linear actuator for neurosurgery.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-9-19
Journal Detail:
Title:  Physics in medicine and biology     Volume:  57     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2012 Sep 
Date Detail:
Created Date:  2012-9-19     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  6347-6369     Citation Subset:  -    
Affiliation:
Varian Medical Systems, 3120 Hansen Way, Palo Alto, CA 94304, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The cost-effectiveness of TNF-inhibitors for the treatment of rheumatoid arthritis in Swedish clinic...
Next Document:  Revisiting the enniatins: a review of their isolation, biosynthesis, structure determination and bio...