Evaluation of global left ventricular function assessment of non-fluorescent electromechanical endocardial mapping compared with biplane left ventricular contrast angiography.
MedLine Citation:
PMID:  20200612     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
Background. Little is known about the diagnostic accuracy of global LV function assessment by electromechanical endocardial mapping (EEM). The aim of the present study was to determine the relationship between global left ventricular (LV) function measured by EEM and biplane left ventricular contrast angiography (LVA) after ST-elevation myocardial infarction (STEMI).Methods. Thirty-seven patients underwent LVA and EEM during routine coronary angiography four months after primary percutaneous intervention for STEMI. Global LV function parameters were available from both techniques in all patients. LVA was regarded as reference standard.Results. All procedures were carried out without adverse events. Average age was 55+/-10 years and 84% were male. EEM showed an overestimation of end-diastolic volume (EDV) and end-systolic volume (ESV) of 6.5 ml and 25.5 ml, respectively. Correlation (r) was 0.84 (p<0.001) for EDV and 0.74 (p<0.001) for ESV. Average left ventricular ejection fraction (LVEF) measured by EEM was 17.2% point (+/-11.3% point) lower compared with LVA (r=0.69, p<0.001).Conclusion. Although global functional parameters by EEM correlated well with LVA, the relatively large differences in terms of absolute values for ventricular volumes and LVEF render the two techniques non-interchangeable for global LV-function-data. (Neth Heart J 2010;18:72-77.).
Authors:
E-S Tan; P A Van der Vleuten; G A J Jessurun; R A Tio; F Zijlstra; I C Van Gelder
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation     Volume:  18     ISSN:  1876-6250     ISO Abbreviation:  Neth Heart J     Publication Date:  2010 Feb 
Date Detail:
Created Date:  2010-03-04     Completed Date:  2011-07-14     Revised Date:  2013-05-29    
Medline Journal Info:
Nlm Unique ID:  101095458     Medline TA:  Neth Heart J     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  72-7     Citation Subset:  -    
Affiliation:
Department of Cardiology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An in vivo comparison of radiofrequency cardiac lesions formed by standard and magnetically steered ...
Next Document:  Measure twice, cut once: pitfalls in the diagnosis of supraventricular tachycardia.