Document Detail


Evaluation of the efficacy and safety of Griflow® Dual, a pre-set two-flow infusion device for intravenous immunoglobulin (Flebogamma® 5%) administration.
MedLine Citation:
PMID:  21959557     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Purpose: A single center, prospective study was performed to assess the efficacy and safety of Griflow® Dual a gravity-fed device for intravenous delivery of human immunoglobulin Flebogamma®. Methods: A total of 2 infusions in 2 visits per patient were assessed using G2 and G3 Griflow® Dual models that provide different flow rates adjusted to the patient's weight. To follow the most common method of intravenous immunoglobulin administration, infusion through the two-way device commenced with the low flow rate capillary (clamp closed) for 30 minutes and continued with the high flow rate, opening both ways. Reliability of flow delivery (average flow rates), adverse events, as well as functionality in daily practice (questionnaire to nurses) were assessed. Results: twenty-five valid infusions were evaluated on 13 subjects. Except for the G2 model with closed clamp in which 14.5% deviation was observed, actual average flow rate values fell well into the maximum 10% deviation permitted with respect to expected charted values (G2: 55 and 142 mL/h; G3: 76 and 189 mL/h). Discrepancies could be explained by patient's arm movements or posture change during infusion. No adverse events related to the study device occurred. In the functionality questionnaires, nurse's comfort and safety of infusion with Griflow® Dual were rated higher than without Griflow® Dual but lower than with infusion pumps. Conclusions: Although it may not be as precise as an infusion pump, Griflow® Dual proved to be a reliable and suitable device to administer Flebogamma® 5%. Correct safety should be confirmed in a larger sample.</p>
Authors:
Argentina Sánchez; Magdalena Alvarez; María Adoración Bustillo; María Carmen García; Margarita Muñoz; Concepción Pacios; Lorena Pizarroso; María Isabel Rubio; Nuria Rodríguez
Related Documents :
16647457 - Fluorescent microspheres reveal different regional blood flow in hyperacutely rejected ...
22574927 - Bivalirudin and post-cardiotomy ecmo: a word of caution.
9697827 - Coronary reserve of high- and low-flow regions in the dog heart left ventricle.
11123247 - Myocardial oxygenation and high-energy phosphate levels during graded coronary hypoperf...
1548807 - Energy metabolism and hematology of white-tailed deer fawns.
7549557 - Umbilical venous line related pericardial effusion in a premature neonate: report of a ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-9-26
Journal Detail:
Title:  The journal of vascular access     Volume:  -     ISSN:  1724-6032     ISO Abbreviation:  -     Publication Date:  2011 Sep 
Date Detail:
Created Date:  2011-9-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100940729     Medline TA:  J Vasc Access     Country:  -    
Other Details:
Languages:  ENG     Pagination:  0     Citation Subset:  -    
Affiliation:
La Paz University Hospital, Madrid - Spain.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Catheter-based renal denervation for drug-resistant hypertension by using a standard electrophysiolo...
Next Document:  Balloon angioplasty for disruption of tunneled dialysis catheter fibrin sheath.