Document Detail


Evaluation of Optimal Acquisition Duration or Injected Activity for Pediatric 18F-FDG PET/CT.
MedLine Citation:
PMID:  21680684     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Pediatric (18)F-FDG dosing and acquisition durations are generally based on coarse extrapolation from adult guidelines. This study sought to determine whether shorter acquisition durations or a lower (18)F-FDG injected activity could be used for pediatric (18)F-FDG PET/CT examinations while maintaining diagnostic utility. Reduction of overall scan time potentially reduces motion artifacts, improves patient comfort, and decreases length of sedation. Alternatively, decreased (18)F-FDG dose minimizes radiation risk. METHODS: Fourteen whole-body (18)F-FDG PET/CT examinations were performed on 13 patients (weight, 13-109 kg; age range, 1-23 y) with a weight-based injected activity (5.3 MBq/kg [0.144 mCi/kg]), fixed acquisition durations (3 min/field of view [FOV] if < 22 kg, 5 min/FOV if > 22 kg), and list-mode acquisition. For each examination, the list-mode data were truncated to form multiple datasets with shorter acquisition durations down to a minimum of 1 min/FOV (i.e., 1, 2, 3, 4, and 5 min/FOV data were formed from single 5 min/FOV acquisition). Fifty-six image volumes were generated, randomized, and reviewed in a masked manner with corresponding CT image volumes by 5 radiologists. Overall, subjective adequacy and objective lesion detection accuracy by body region were evaluated. RESULTS: All examinations with maximum acquisition duration were graded as adequate and were used as the reference standard for detection accuracy. For patients less than 22 kg, 1 of the 3 PET/CT examinations was graded as inadequate for clinical tasks when acquisition duration was reduced to 2 min/FOV, and all examinations were graded as inadequate when reduced to 1 min/FOV. For patients more than 22 kg, all 3-5 min/FOV studies were graded as adequate, and 2 of the 9 studies were graded as inadequate for 2 min/FOV studies. Lesion detection accuracy was perfect for acquisition times between 3 min/FOV and 5 min/FOV for all regions of the body. However, lesion detection became less accurate when imaging acquisition time was reduced more than 40%. CONCLUSION: Evaluation of image volumes generated from simulated shorter acquisition durations suggests that imaging times for larger patients (>22 kg) can be reduced from 5 min/FOV to 3 min/FOV without a loss of diagnostic utility. Using decreased acquisition times as a surrogate for (18)F-FDG dose, we reduced (18)F-FDG dose by approximately 40% when all patients were scanned for 5 min/FOV.
Authors:
Adam M Alessio; Marla Sammer; Grace S Phillips; Vivek Manchanda; Brandt C Mohr; Marguerite T Parisi
Related Documents :
15578294 - Comparison of capsule endoscopy and magnetic resonance imaging for the detection of pol...
11243344 - On the use of pediatric phantoms in the dose evaluation during computed tomography (ct)...
19933644 - Ct colonography with decreased purgation: balancing preparation, performance, and patie...
16498094 - Comparison of angular and combined automatic tube current modulation techniques with co...
8632544 - Magnetic resonance imaging after intraurethral collagen injected for stress urinary inc...
19059024 - Osteoarthritis: current role of imaging.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-6-16
Journal Detail:
Title:  Journal of nuclear medicine : official publication, Society of Nuclear Medicine     Volume:  -     ISSN:  1535-5667     ISO Abbreviation:  -     Publication Date:  2011 Jun 
Date Detail:
Created Date:  2011-6-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0217410     Medline TA:  J Nucl Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Radiology, University of Washington, Seattle, Washington.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A PET Brain Reporter Gene System Based on Type 2 Cannabinoid Receptors.
Next Document:  Hepatic blood perfusion measured by 3-minute dynamic 18F-FDG PET in pigs.