Abstract/OtherAbstract:
OBJECTIVE: For pandemic influenza outbreaks, the Institute of Medicine has recommended using a surgical mask cover (SM) over N95 filtering facepiece respirators (FFRs) among healthcare workers as one strategy to avoid surface contamination of the FFR which would extend its efficacy and reduce the threat of exhausting FFR supplies. The objective of this investigation was to measure breathing air quality and breathing resistance when using FFRs with US Food and Drug Administration-cleared SM and without SM. METHODS: Thirty National Institute for Occupational Safety and Health (NIOSH)-approved FFR models with and without SM were evaluated using the NIOSH Automated Breathing and Metabolic Simulator (ABMS) through six incremental work rates. RESULTS: Generally, concentrations of average inhaled CO(2) decreased and average inhaled O(2) increased with increasing O(2) consumption for FFR+SM and FFR-only. For most work rates, peak inhalation and exhalation pressures were statistically higher in FFR+SM as compared with FFR-only. The type of FFR and the presence of exhalation valves (EVs) had significant effects on average inhaled CO(2), average inhaled O(2), and breathing pressures. The evidence suggests that placement of an SM on one type of FFR improved inhaled breathing gas concentrations over the FFR without SM; the placement of an SM over an FFR+EV probably will prevent the EV from opening, regardless of activity intensity; and, at lower levels of energy expenditure, EVs in FFR do not open either with or without an SM. CONCLUSIONS: The differences in inhaled gas concentrations in FFR+SM and FFR-only were significant, especially at lower levels of energy expenditure. The orientation of the SM on the FFR may have a significant effect on the inhaled breathing quality and breathing resistance, although the measurable inhalation and exhalation pressures caused by SM over FFR for healthcare users probably will be imperceptible at lower activity levels.
Authors:
Edward James Sinkule; Jeffrey Bryon Powell; Fredric Lee Goss
Related Documents :
22370686 - Complete respiratory support with avco2r and cpap-mimic ventilation for total gas excha...
9876316 - Vagal nerve stimulation releases vasoactive intestinal peptide which significantly incr...
22633126 - Pulmonary artery pressure in cystic fibrosis adults: characteristics, clinical correlat...
22766676 - Mri evidence of impaired csf homeostasis in obesity-associated idiopathic intracranial ...
16084286 - Newer paradigms in renal replacement therapy: will they alter cardiovascular outcomes?
3664996 - Inconsistency of the slope and the volume intercept of the end-systolic pressure-volume...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-29
Journal Detail:
Title:  The Annals of occupational hygiene     Volume:  -     ISSN:  1475-3162     ISO Abbreviation:  Ann Occup Hyg     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0203526     Medline TA:  Ann Occup Hyg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention , Pittsburgh, PA, USA;
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  New aspects of surgery for pancreatic cancer : Principles, results and evidence.
Next Document:  Use of dynamic wound closure system in conjunction with vacuum-assisted closure therapy in delayed c...