Document Detail


Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device.
MedLine Citation:
PMID:  20436362     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
PURPOSE: (a) To investigate whether the ICare rebound tonometer can provide accurate measurements of intraocular pressure (IOP) in the hands of an inexperienced user compared with ICare measurements and Goldmann tonometry by a trained technician and (b) to assess the intrauser reproducibility of IOP measurements and the learning curve among patients using the ICare rebound tonometer.
METHODS: A trained technician used the ICare rebound tonometer to measure the IOP of the right eye of 100 glaucoma patients. The technician then instructed each patient on use of the ICare tonometer. Each patient then measured his/her own pressure using the ICare tonometer. Finally, a different technician, who was masked to both of the earlier readings, measured IOP by Goldmann applanation tonometry. Thirty patients repeated the ICare measurement 3 times (once every 5 min) 20 minutes after the initial IOP measurement.
RESULTS: Of the 100 patients, 82 of patient ICare and the technician ICare readings were within 3 mm Hg of each other, and 75 of the patient ICare and Goldmann applanation tonometry measurements were within 3 mm Hg of each other. Intraclass correlations between self-administered ICare measurements 1and 2, 1 and 3, and 2 and 3 were 0.69, 0.71 and 0.81, respectively.
CONCLUSION: In this study, the ICare rebound tonometer was accurate and reliable in the hands of patients. Patients can easily learn to self-administer this test, possibly allowing for home monitoring of IOP.
Authors:
Sanjay Asrani; Ashmita Chatterjee; David K Wallace; Cecilia Santiago-Turla; Sandra Stinnett
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of glaucoma     Volume:  20     ISSN:  1536-481X     ISO Abbreviation:  J. Glaucoma     Publication Date:  2011 Feb 
Date Detail:
Created Date:  2011-02-03     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9300903     Medline TA:  J Glaucoma     Country:  United States    
Other Details:
Languages:  eng     Pagination:  74-9     Citation Subset:  IM    
Affiliation:
*Duke University Eye Center, Durham †University of North Carolina Medical School, Chapel Hill, NC.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The Validity of Screening For Open-angle Glaucoma in High-risk Populations With Single-test Screenin...
Next Document:  Automatic, Operator-adjusted, and Manual Disc-definition for Optic Nerve Head and Retinal Nerve Fibe...