Evaluation of the Beckman Synchron CX4 clinical chemistry analyzer in a hospital laboratory.
MedLine Citation:
PMID:  2313469     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The Beckman Synchron CX4 random-access multianalyzer was evaluated in a medium sized hospital laboratory. The instrument does end-point, rate, and multipoint assays and carries on-board reagents for 24 tests. In addition to predefined tests, the instrument can be programmed for 100 user-defined tests; these are stored on the hard disk and can utilize up to three component reagents each. The throughput is 200 tests per hour. There is stat testing capability. In our evaluation, within-run and between-run precision and linearity were good, and no reagent carryover was detected. There was good correlation with the in-house methodology for the 19 tests evaluated. A disadvantage at the time of evaluation was interference by elevated bilirubin on creatinine, phosphorus, uric acid, and triglycerides. This problem of interference is being addressed by the manufacturer.
Authors:
T Ambus; N Korogyi; F DeCampos; B Groom; V T Innanen
Related Documents :
24857979 - Defensive behaviour of apis mellifera against vespa velutina in france: testing whether...
23959709 - The relationship between total and regional corpus callosum atrophy, cognitive impairme...
23716289 - Role of mdct coronary angiography in the clinical setting: economic implications.
24961689 - How i do it: judging appropriateness for tte and tee.
21649429 - Peer reviewed: in situ bioremediation: defining the limits.
2643799 - Nonculture methods for detection and identification of microorganisms in clinical speci...
6463799 - Early detection of colorectal cancer using faecal occult blood tests.
22114229 - The impact of a media campaign on cervical screening knowledge and self-efficacy.
16279479 - Interexaminer reliability and validity for diagnosis of temporomandibular disorders of ...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of clinical laboratory analysis     Volume:  4     ISSN:  0887-8013     ISO Abbreviation:  J. Clin. Lab. Anal.     Publication Date:  1990  
Date Detail:
Created Date:  1990-04-26     Completed Date:  1990-04-26     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  8801384     Medline TA:  J Clin Lab Anal     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  120-5     Citation Subset:  IM    
Affiliation:
Department of Clinical Biochemistry, University of Toronto, Ontario, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Autoanalysis / instrumentation*,  standards
Bilirubin / blood
Blood Chemical Analysis / instrumentation*,  standards
Chemistry, Clinical / instrumentation*,  standards
Evaluation Studies as Topic
Hemolysis
Hyperlipidemias / blood
Laboratories, Hospital
Quality Control
Chemical
Reg. No./Substance:
635-65-4/Bilirubin

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Impairment of jacalin binding to serum IgA in IgA nephropathy.
Next Document:  An enzyme-linked immunosorbent assay for the detection of antitetanus toxoid antibody using aluminum...