Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters. |
| | |
Authors:
|
T W M Grimbergen; M Figel; A M Romero; H Stadtmann; A F McWhan |
Related Documents
:
|
21321986 - Compulsive exercise: the role of personality, psychological morbidity, and disordered e... 18845966 - Effect of exercise training intensity on abdominal visceral fat and body composition. 21591576 - Association between cardiac functional capacity and parameters of tissue doppler imagin... 22110966 - Endurance and resistance training in radically treated respiratory cancer patients: a p... 3813196 - The response of the nasal airway to exercise. 20168256 - Comparison of two different resistance training intensities on excess post-exercise oxy... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2011-1-17 |
Journal Detail:
|
Title: Radiation protection dosimetry Volume: - ISSN: 1742-3406 ISO Abbreviation: - Publication Date: 2011 Jan |
Date Detail:
|
Created Date: 2011-1-18 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 8109958 Medline TA: Radiat Prot Dosimetry Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
NRG, Radiation and Environment, Individual Monitoring, Arnhem, The Netherlands. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: MONTE CARLO SIMULATIONS OF THE ELECTRIC FIELD CLOSE TO THE BODY IN REALISTIC ENVIRONMENTS FOR APPLIC...
Next Document: MONTE CARLO DETERMINATION OF THE CONVERSION COEFFICIENTS HP(3)/Ka IN A RIGHT CYLINDER PHANTOM WITH '...