Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform.
MedLine Citation:
PMID:  23366455     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
There is increasing interest in non-invasive estimation of central aortic waveform parameters in the clinical setting. However, controversy has arisen around radial tonometric based systems due to the requirement of a trained operator or lack of ease of use, especially in the clinical environment. A recently developed device utilizes a novel algorithm for brachial cuff based assessment of aortic pressure values and waveform (SphygmoCor XCEL, AtCor Medical). The cuff was inflated to 10 mmHg below an individual's diastolic blood pressure and the brachial volume displacement waveform recorded. The aortic waveform was derived using proprietary digital signal processing and transfer function applied to the recorded waveform. The aortic waveform was also estimated using a validated technique (radial tonometry based assessment, SphygmoCor, AtCor Medical). Measurements were taken in triplicate with each device in 30 people (17 female) aged 22 to 79 years of age. An average for each device for each individual was calculated, and the results from the two devices were compared using regression and Bland-Altman analysis. A high correlation was found between the devices for measures of aortic systolic (R(2)=0.99) and diastolic (R(2)=0.98) pressure. Augmentation index and subendocardial viability ratio both had a between device R(2) value of 0.82. The difference between devices for measured aortic systolic pressure was 0.5±1.8 mmHg, and for augmentation index, 1.8±7.0%. The brachial cuff based approach, with an individualized sub-diastolic cuff pressure, provides an operator independent method of assessing not only systolic pressure, but also aortic waveform features, comparable to existing validated tonometric-based methods.
Authors:
Mark Butlin; Ahmad Qasem; Alberto P Avolio
Related Documents :
2325355 - Doppler measurement of cardiac output across prosthetic mitral valves.
12914665 - Early diastolic filling dynamics in diastolic dysfunction.
15335425 - Decreases in ventricular volume correlate with decreases in ventricular pressure in idi...
23815535 - Effects of nebivolol on aortic compliance in patients with diabetes and maximal renin a...
18716365 - Impact of renin-angiotensin system inhibition on microalbuminuria in type 2 diabetes: a...
9309745 - The postural orthostatic tachycardia syndrome: a neurocardiogenic variant identified du...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference     Volume:  2012     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2012  
Date Detail:
Created Date:  2013-01-31     Completed Date:  2013-08-26     Revised Date:  2014-08-21    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2591-4     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Arterial Pressure / physiology*
Blood Pressure Determination / instrumentation*
Female
Humans
Male
Middle Aged
Young Adult

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pulse rate estimation using hydraulic bed sensor.
Next Document:  Automatic identification and accurate temporal detection of inhalations in asthma inhaler recordings...