Document Detail


Establishing a reference value for the frequency of fetal movements using modified 'count to 10' method.
MedLine Citation:
PMID:  18588609     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
AIMS: To establish a reference value for the frequency of fetal movements perceived by the mother during the second half of pregnancy. METHODS: The study subjects consisted of 705 low risk Japanese pregnant women who continuously received antenatal care. We asked women to record the time required to perceive 10 fetal movements ('count to 10' time) everyday. We asked women to record it, not at a fixed time (i.e. evening time), but whenever they felt the fetus move the most actively. The position during counting (i.e. sitting position) was also not specified, and thus we named this method as modified 'count to 10' method. Satisfactory recordings were obtained from 690 women, which we used for analysis. RESULTS: The 'count to 10' time was almost the same from 22 weeks (10.9; 7.3-18.0 (median; interquartile range)) until 32 weeks (10.0; 6.2-15.6), and it Thirty-two weeks showed the shortest time, which gradually increased toward 40 weeks (14.8; 9.5-24.0). Its 90th percentile was approximately 25 and 35 min at 22-36 weeks and at 37-40 weeks, respectively. CONCLUSIONS: For the first time we established a reference value for perceived fetal movements throughout the second half of pregnancy. The present modified 'count to 10' method requires less time than the previous method. Approximately 98% (690/705) of women gave us satisfactory recordings. This reference value may be of use in identifying mothers with decreased fetal movements.
Authors:
Tomoyuki Kuwata; Shigeki Matsubara; Takashi Ohkusa; Akihide Ohkuchi; Akio Izumi; Takashi Watanabe; Mitsuaki Suzuki
Related Documents :
9475359 - Computerised analysis of fetal behaviour.
1603499 - Coupling of fetal movement and fetal heart rate accelerations as an indicator of fetal ...
2698309 - Power spectral analysis of the heart rate of the human fetus at 26 and 36 weeks of gest...
605799 - Arhinencephaly (holoprosencephaly) associated with external hydrocephaly.
8233279 - Does doppler-detected fetal movement decrease the incidence of nonreactive nonstress te...
15073919 - Nefazodone in community use: the results of prescription-event monitoring.
2850989 - The human placental bed: histology, immunohistochemistry and pathology.
8949569 - Growth hormone, insulin-like growth factor i and its binding proteins 1 and 3 in last t...
22517619 - Conceptus-endometrium crosstalk during maternal recognition of pregnancy in cattle.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The journal of obstetrics and gynaecology research     Volume:  34     ISSN:  1341-8076     ISO Abbreviation:  J. Obstet. Gynaecol. Res.     Publication Date:  2008 Jun 
Date Detail:
Created Date:  2008-06-30     Completed Date:  2008-09-04     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9612761     Medline TA:  J Obstet Gynaecol Res     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  318-23     Citation Subset:  IM    
Affiliation:
Department of Obstetrics and Gynecology, Jichi Medical University, Yakushiji, Shimotsuke, Tochigi, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Female
Fetal Death / diagnosis
Fetal Movement / physiology*
Gestational Age*
Humans
Japan
Pregnancy
Reference Values
Time Factors

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  ACE and MTHFR gene polymorphisms in unexplained recurrent pregnancy loss.
Next Document:  Diabetic ketoacidosis in pregnancy tends to occur at lower blood glucose levels: case-control study ...