Errors in frequency parameters of EMG power spectra.
MedLine Citation:
PMID:  1748442     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Frequency shifts in random signals, e.g., EMG or Doppler ultrasound, can be followed by monitoring one or more parameters of the power spectrum. When such a frequency parameter is determined over a finite length of the signal, a random error and sometimes a systematic error or bias are introduced. Approximate expressions, in terms of moments of the power spectrum, have been derived for bias and standard deviation of the estimates for mean frequency, zero-crossing frequency, and fractile frequency (of which the median frequency is a special case). Experimental results from surface EMG recordings of three human muscles in constant force isometric contractions were in agreement with the theoretical predictions. In this case the mean frequency had the smallest random error. It turned out that the measured values of the zero-crossing frequency can deviate considerably from the predictions by the Rice formula when the amplitude distribution is not exactly Gaussian. In the presence of noise, all frequency parameters show a systematic deviation, depending on the signal-to-noise ratio. In addition to known results on this deviation for mean and zero-crossing frequency, an exact and an approximate expression for the fractile frequency are given. In the case of EMG plus wide-band white noise, the median frequency has the best immunity to noise.
Authors:
A L Hof
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  IEEE transactions on bio-medical engineering     Volume:  38     ISSN:  0018-9294     ISO Abbreviation:  IEEE Trans Biomed Eng     Publication Date:  1991 Nov 
Date Detail:
Created Date:  1992-01-17     Completed Date:  1992-01-17     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0012737     Medline TA:  IEEE Trans Biomed Eng     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1077-88     Citation Subset:  IM    
Affiliation:
University of Groningen, Laboratory of Medical Physics, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electromyography*
Electrophysiology
Humans
Models, Biological

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An assessment of variable thickness and fiber orientation of the skeletal muscle layer on electrocar...
Next Document:  Computer analysis of the electrocardiogram during esophageal pacing cardiac stress.