Envelope amplitude analysis following narrow-band filtering: a technique for ultrasonic tissue characterization.
MedLine Citation:
PMID:  3306304     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Ultrasonic waveforms backscattered from tissue simulating phantoms and from normal and cirrhotic human livers in vivo were digitized to a standard dynamic range prior to envelope detection and determination of envelope amplitude distributions. For 11 individual narrow-band Gaussian-shaped filters of -6 dB bandwidth 200 kHz, and of center frequencies from 2 to 4 MHz, envelope amplitude distributions were plotted and mean values of the values distributions computed. Analysis of data was performed for data from a phantom containing only relatively small graphite scatters (less than 170 mu), and a similar phantom to which glass spheres 0.5 mm in diameter had been added homogeneously. For lower center frequency narrow-band filters, significantly more high-amplitude occurrences were observed for data from the phantom to which glass spheres had been added. Higher center frequency narrow-band filters gave significantly more high-amplitude occurrences for the phantom containing only small scatters. Similar data analysis was performed for in vivo human liver data from ten normal subjects and five patients with known cirrhosis of the liver. For the cirrhotic and normal livers, data analysis using narrow-band filters of relatively low center frequency resulted in more high- amplitude occurrences for cirrhotic, compared to normal liver; the converse was true for narrow-band filtration at relatively high center frequencies. Determination of mean amplitude following narrow-band filtration with a filter centered at 3.4 MHz was found to be quite repeatable for the normal and cirrhotic liver data; analysis of variance showed the measurement was 94.1% a function of the subject examined, and 5.9% related to the data acquisition session.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
F G Sommer; R A Stern; P J Howes; H Young
Related Documents :
8201114 - Profile analysis and comodulation detection differences using narrow bands of noise and...
20366114 - Band gap narrowing of titanium oxide semiconductors by noncompensated anion-cation codo...
16090954 - Surface-plasmon-assisted guiding of broadband slow and subwavelength light in air.
19550574 - Nano-lithographically fabricated titanium dioxide based visible frequency three dimensi...
19446034 - Ideal observer analysis of signal quality in retinal circuits.
10321254 - Spatial characteristics of the second-order visual pathway revealed by positional adapt...
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Medical physics     Volume:  14     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:    1987 Jul-Aug
Date Detail:
Created Date:  1987-10-07     Completed Date:  1987-10-07     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  627-32     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Humans
Liver / anatomy & histology*,  pathology
Liver Cirrhosis / diagnosis*
Reference Values
Ultrasonography / methods*
Grant Support
ID/Acronym/Agency:
5 K04 CA00960/CA/NCI NIH HHS; 5R01 CA37483/CA/NCI NIH HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Relevance of the salt-hypertension hypothesis to the community control of hypertension.
Next Document:  Estimation of tissue parameters derived from reflected ultrasound.