| Endpoints for Hemodialysis Access Procedures: Correlation between Fistulography and Intraaccess Blood Flow Measurements. | |
| | |
MedLine Citation:
|
PMID: 22115580 Owner: NLM Status: In-Data-Review |
Abstract/OtherAbstract:
|
PURPOSE: The success of percutaneous interventions on stenotic hemodialysis prosthetic grafts and autogenous fistulas is assessed by comparing vessel diameter before and after treatment. These changes do not correlate with gold standard access blood flow (ABF) measurements obtained during hemodialysis. The AngioFlow (AngioDynamics, Inc, Queensbury, New York) calculates real-time blood flow through access circuits and may provide more physiologically relevant data in the interventional suite. This study compares angiographic vessel diameter and access circuit flow rates obtained with the AngioFlow Meter before and after percutaneous interventions on stenotic hemodialysis prosthetic grafts and autogenous fistulas ABF measurements obtained during hemodialysis. MATERIALS AND METHODS: Angiographic images and AngioFlow measurements for 76 procedures in 35 patients undergoing hemodialysis with arteriovenous grafts or fistulas were analyzed retrospectively. Correlations between ABF, fistulography, and AngioFlow measurements before and after treatment were computed. Regression analyses of AngioFlow measurements and measurements after ABF were performed to account for confounding factors. Time to failure of treatment was modeled in first-time patients stratified by AngioFlow values obtained after treatment. Only patients with ABF measurements obtained within 5 weeks of intervention were included. RESULTS: Correlations between initial ABF and fistulography measurement (ρ = 0.781), initial ABF and AngioFlow (ρ = 0.675), and final AngioFlow and ABF measurement (ρ = 0.798) were statistically significant. The correlation between final ABF and AngioFlow was significantly stronger than final ABF and fistulography (difference = 0.418, 95% bootstrap confidence interval [CI] [0.054, 0.914]). AngioFlow values and access survival after treatment did not show significant correlation. CONCLUSIONS: AngioFlow measurements performed after treatment correlate more strongly with hemodialysis ABF values than fistulography measures. Further studies are needed to determine the target AngioFlow value obtained after treatment that is associated with the greatest survival benefit for access circuits. |
| | |
Authors:
|
Anurag Goyal; Robert C Orth; Rulan S Parekh; Tanya Wolfson; Anthony Gamst; Michael D Kuo |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Journal of vascular and interventional radiology : JVIR Volume: 22 ISSN: 1535-7732 ISO Abbreviation: J Vasc Interv Radiol Publication Date: 2011 Dec |
Date Detail:
|
Created Date: 2011-11-25 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9203369 Medline TA: J Vasc Interv Radiol Country: United States |
Other Details:
|
Languages: eng Pagination: 1733-9 Citation Subset: IM |
Copyright Information:
|
Copyright © 2011. Published by Elsevier Inc. |
Affiliation:
|
Department of Radiology, University of California San Diego Medical Center, San Diego, California. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Patients' Perspective about Risks and Benefits of Treatment for Peripheral Arterial Disease.
Next Document: Long-Term Follow-Up of Treatment of Pulmonary Arteriovenous Malformations with AMPLATZER Vascular Pl...