Document Detail


Endotension is influenced by wall compliance in a latex aneurysm model.
MedLine Citation:
PMID:  14652836     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: Even though endovascular aneurysm repair (EVAR) creates a closed chamber except for patent branches, the intra-sac pressure is never zero. This study was designed to investigate whether, and to what extent, aneurysm wall compliance influences intra-sac pressure. DESIGN: In vitro experimental study. METHODS: Aneurysm models with six and 12 latex layers were produced, resulting in elastic and stiff circumferential compliance (3.5 +/- 0.5 and 0.9 +/- 0.3%/100 mmHg, respectively). The models with an 18 mm internal neck and maximum aneurysm diameter of 60 mm were inserted into an in vitro circulation system. The systemic mean pressure (SPmean) was varied from 50 to 120 mmHg. After the aneurysm was excluded with a knitted polyethylene graft, aneurysm sac mean pressure (ASPmean) and aneurysm sac pulse pressure (ASPpulse) were measured. Data are presented as mean +/- SD. Statistics were performed using repeated measurements of variance; p<0.05 was considered significant. RESULTS: In the model EVAR created a closed chamber without endoleak, but with an aneurysm sac pressure related to wall compliance. In the elastic aneurysm model with six latex coats the aneurysm sac mean pressure (ASPmean) and the aneurysm sac pulse pressure (ASPpulse) at all systemic pressures were significantly lower than they were in the stiffer model with 12 latex coats (p<0.05). At a SPmean of 90 mmHg, the ASPmean was 21.0 +/- 0.9 mmHg (six latex coats) and 26.0 +/- 0.2 mmHg (12 latex coats) (p<0.05), the ASPpulse was 5.7 +/- 0.2 mmHg (six latex coats) and 8.8 +/- 0.3 mmHg (12 latex coats) (p<0.05). CONCLUSIONS: This in vitro model demonstrated that the aneurysm sac mean pressure (ASPmean) and the aneurysm sac pulse pressure (ASPpulse) were significantly influenced by the compliance of the aneurysm wall. These data highlight the need for further studies regarding endotension.
Authors:
M Gawenda; P Knez; St Winter; G Jaschke; G Wassmer; Th Schmitz-Rixen; J Brunkwall
Related Documents :
7586346 - Intracoronary heparin delivery in humans. acute feasibility and long-term results.
10941546 - Immediate and late clinical and angiographic outcomes after gfx coronary stenting: is h...
25298526 - Local ph domains regulate nhe3 mediated na+ reabsorption in the renal proximal tubule.
9136186 - Dimensions and mechanical properties of porcine aortic segments determined by combined ...
17970236 - The use of non-invasive ventilation in the treatment of acute cardiogenic pulmonary edema.
17016406 - The acute management of head injury.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery     Volume:  27     ISSN:  1078-5884     ISO Abbreviation:  Eur J Vasc Endovasc Surg     Publication Date:  2004 Jan 
Date Detail:
Created Date:  2003-12-03     Completed Date:  2004-01-22     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9512728     Medline TA:  Eur J Vasc Endovasc Surg     Country:  England    
Other Details:
Languages:  eng     Pagination:  45-50     Citation Subset:  IM    
Affiliation:
Division of Vascular Surgery, Department of Visceral and Vascular Surgery, University of Cologne, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aortic Aneurysm, Abdominal / physiopathology*,  surgery*
Blood Vessel Prosthesis Implantation*
Compliance
Latex
Models, Biological
Stress, Mechanical
Chemical
Reg. No./Substance:
0/Latex

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A cautionary case: the SynerGraft vascular prosthesis.
Next Document:  A UK multi-centre experience with a second-generation endovascular stent-graft: results from the Zen...