Document Detail


Electrophysiology of atrial fibrillation and its prevention by coronary sinus pacing.
MedLine Citation:
PMID:  9704357     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Atrial fibrillation (AF) is a re-entrant rhythm, and patients with AF have intra-atrial conduction abnormalities as evidenced by prolonged P-wave duration, abnormal SAECG of P wave, fragmented atrial electrograms and greater intra-atrial conduction delays in response to APDs. Our previous work has proposed that intra-atrial conduction delays and dispersion of refractoriness during extrastimulus testing are site dependent; high right atrial (HRA) stimulation results in marked prolongation of intra-atrial conduction times and AF, whereas distal coronary sinus (CS) stimulation is associated with minimal conduction delays and absence of AF inducibility. Patients with AF induction during HRA stimulation also manifest non-uniform anisotropic conduction in the region of the posterior triangle of Koch. We postulated that if the posterior triangle of Koch is a critical area for re-entry that initiates AF, then prevention of early activation of the posterior triangle may prohibit AF induction by HRA APDs. Distal CS pacing pre-excites the posterior triangle in relation to HRA activation, therefore a subsequent HRA APD will activate the posterior triangle with a longer coupling interval. AF induction by HRA APDs following HRA pacing is prevented when same HRA APDs follow distal CS pacing. We propose that distal CS pacing eliminates the propensity of HRA extrasystoles to induce AF. This observation may have further clinical applicability in AF prevention.
Authors:
P Papageorgiou; K Monahan; F Anselme; C Kirchhof; M E Josephson
Related Documents :
7527757 - The treatment of atrial fibrillation. an evaluation of drug therapy, electrical modalit...
17174237 - Hemodynamic and neurohormonal predictors and consequences of the development of atrial ...
8066487 - Community social change and mortality.
12715847 - Impact of atrial fibrillation on the voltage of bipolar signals acquired from the left ...
22267307 - Validation of the 3-lead tele-ecg versus the 12-lead tele-ecg and the conventional 12-l...
20299007 - Ambulatory and challenge-associated heart rate variability measures predict cardiac res...
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Seminars in interventional cardiology : SIIC     Volume:  2     ISSN:  1084-2764     ISO Abbreviation:  Semin Interv Cardiol     Publication Date:  1997 Dec 
Date Detail:
Created Date:  1998-10-14     Completed Date:  1998-10-14     Revised Date:  2005-11-16    
Medline Journal Info:
Nlm Unique ID:  9606070     Medline TA:  Semin Interv Cardiol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  227-32     Citation Subset:  IM    
Affiliation:
Clinical Cardiac Electrophysiology Laboratories, Harvard-Thorndike Electrophysiology Institute, Boston, MA, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Atrial Fibrillation / physiopathology*,  prevention & control
Cardiac Pacing, Artificial*
Electrocardiography
Heart Conduction System / physiopathology*
Humans

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The role of pacemaker therapy in the prevention of atrial fibrillation.
Next Document:  Internal atrial defibrillation: lessons learnt from experimental studies.