Electron beam treatment verification using measured and Monte Carlo predicted portal images.
MedLine Citation:
PMID:  16237235     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Electron beam treatments may benefit from techniques to verify patient positioning and dose delivery. This is particularly so for complex techniques such as mixed photon and electron beam radiotherapy and electron beam modulated therapy. This study demonstrates that it is possible to use the bremsstrahlung photons in an electron beam from a dual scattering foil linear accelerator to obtain portal images of electron beam treatments. The possibility of using Monte Carlo (MC) simulations to predict the electron beam treatment portal images was explored. The MC code EGSnrc was used to model a Varian CL21EX linear accelerator (linac) and to characterize the bremsstrahlung photon production in the linac head. It was found that the main sources of photons in the electron beam are the scattering foils, the applicator and the beam-shaping cut-out. Images were acquired using the Varian CL21EX linac and the Varian aS500 electronic portal imager (EPI); four electron energies (6, 9, 12, 16 MeV), and different applicator and cut-out sizes were used. It was possible to acquire images with as little as 10.7 MU per image. The contrast, the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), the resolution and an estimate of the modulated transfer function (MTF) of the electron beam portal images were computed using a quality assurance (QA) phantom and were found to be comparable to those of a 6 MV photon beam. Images were also acquired using a Rando anthropomorphic phantom. MC simulations were used to model the aS500 EPID and to obtain predicted portal images of the QA and Rando phantom. The contrast in simulated and measured portal images agrees within +/-5% for both the QA and the Rando phantom. The measured and simulated images allow for a verification of the phantom positioning by making sure that the structure edges are well aligned. This study suggests that the Varian aS500 portal imager can be used to obtain patient portal images of electron beams in the scattering foil linacs.
Authors:
G Jarry; F Verhaegen
Related Documents :
16725225 - Quantification of pore clogging characteristics in potential permeable reactive barrier...
1854535 - Development of an electronic prescription processing option: an aid for general practice.
12201425 - Commissioning and quality assurance of an optically guided three-dimensional ultrasound...
7591905 - Clinical use of a digital simulator for rapid setup verification in high dose rate brac...
18846195 - Improved speckle projection profilometry for out-of-plane shape measurement.
23037035 - Reconstruction of objects above and below the objective focal plane with dimensional fi...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2005-10-12
Journal Detail:
Title:  Physics in medicine and biology     Volume:  50     ISSN:  0031-9155     ISO Abbreviation:  Phys Med Biol     Publication Date:  2005 Nov 
Date Detail:
Created Date:  2005-10-20     Completed Date:  2006-01-04     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  England    
Other Details:
Languages:  eng     Pagination:  4977-94     Citation Subset:  IM    
Affiliation:
Medical Physics Unit, McGill University, Montreal General Hospital, 1650 Cedar avenue, Montreal, Quebec H3G 1A4, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Computer Simulation
Electrons*
Humans
Image Processing, Computer-Assisted
Models, Statistical
Models, Theoretical
Monte Carlo Method
Particle Accelerators
Phantoms, Imaging
Photons
Radiotherapy / methods*
Radiotherapy Planning, Computer-Assisted / methods
Scattering, Radiation

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound hea...
Next Document:  Polarity effect of the thimble-type ionization chamber at a low dose rate.