Abstract/OtherAbstract:
BACKGROUND: Transapical aortic valve implantation (TAVI) for the treatment of severe aortic stenosis requires the insertion of a large catheter through the left ventricular apex. However, the electrocardiographic (ECG) changes associated with the incision and repair of the left ventricular apex and the potential damage to the conduction system caused by implanting a balloon-expandable valve in aortic position are not known. The objective of our study was to determine the incidence, type, and timing of ECG changes associated with TAVI. METHODS: The standard 12-lead ECGs of 33 consecutive patients (mean age 81 +/- 9 years, 13 men) diagnosed with symptomatic severe aortic stenosis (valve area 0.62 +/- 0.16 cm(2)) who underwent TAVI with an Edwards-SAPIEN valve were analyzed at baseline (within 24 hours before the procedure), immediately (within 6 hours) after the procedure, at hospital discharge, and at 1-month follow-up. RESULTS: There were no procedural deaths, and 30-day mortality was 6%. The incidence of complete left ventricular branch block (LBBB) and left anterior hemiblock (LAHB) increased from 9% and 3% at baseline to 27% and 36% after the procedure, respectively (P < .03 for both). A lower (ventricular) position of the valve relative to the hinge point of the anterior mitral leaflet was associated with a higher incidence of new LBBB (35% vs 0%, P = .029); and a greater valve size-aortic annulus ratio, with the occurrence of new LAHB (1.20 +/- 0.07 vs 1.14 +/- 0.06, P = .021). At 1-month follow-up, the rate of LBBB and LAHB decreased to 13% and 10%, respectively (P = not significant compared with baseline). There were no cases of new atrioventricular block, and no patient needed pacemaker implantation. Transient (<48 hours) ST-elevation changes, mostly in the anterior and/or lateral leads, occurred in 6 patients (18%) immediately after the procedure; but only 1 of these patients presented new Q waves at 1-month follow-up. CONCLUSIONS: Transapical aortic valve implantation was associated with a significant but transient (<1 month) increase in LBBB and LAHB, with no patient requiring pacemaker implantation. These changes were partially related to both lower (more ventricular) valve positioning and greater valve oversizing. Transient (<48 hours) ST-segment elevation changes occurred in about one fifth of the patients after the procedure, but only a minority developed new Q waves in the ECG.
Authors:
Marcos Gutiérrez; Josep Rodés-Cabau; Rodrigo Bagur; Daniel Doyle; Robert DeLarochellière; Sebastien Bergeron; Jerôme Lemieux; Jacques Villeneuve; Mélanie Côté; Olivier F Bertrand; Paul Poirier; Marie-Annick Clavel; Philippe Pibarot; Eric Dumont
Related Documents :
1781069 - Change in amplitude distributions of doppler spectrograms recorded below the aortic val...
3078559 - Prospective validation of detection and quantitative assessment of chronic aortic regur...
7351849 - Preoperative m-mode echocardiography as a predictor of surgical results in chronic aort...
9487469 - Diagnostic accuracy and role of intraoperative biplane transesophageal echocardiography...
9544869 - Aortic stiffening does not predict coronary and extracoronary atherosclerosis in asympt...
11174789 - Cardiac response and complications during endovascular repair of abdominal aortic aneur...
11174439 - Abnormal right coronary artery flow and multiple right ventricular myocardial infarctio...
20934559 - Study design and rationale for the clinical outcomes of the stability trial (stabilizat...
1082319 - The lesser saphenous vein. an alternative graft for coronary revascularization.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  American heart journal     Volume:  158     ISSN:  1097-6744     ISO Abbreviation:  Am. Heart J.     Publication Date:  2009 Aug 
Date Detail:
Created Date:  2009-07-21     Completed Date:  2009-08-21     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0370465     Medline TA:  Am Heart J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  302-8     Citation Subset:  AIM; IM    
Affiliation:
Quebec Heart and Lung Institute, Quebec, Quebec G1V 4G5, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Aortic Valve Stenosis / surgery*
Aortography
Bundle-Branch Block / epidemiology
Creatine Kinase, MB Form / analysis
Electrocardiography*
Female
Heart Catheterization / adverse effects,  methods
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation / adverse effects,  methods*
Humans
Male
Time Factors
Chemical
Reg. No./Substance:
EC 2.7.3.2/Creatine Kinase, MB Form

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Use of myocardial deformation imaging to detect preclinical myocardial dysfunction before convention...
Next Document:  Left atrial function assessed by real-time 3-dimensional echocardiography is related to right ventri...