Electrocardiogram-Synchronized Rotational Speed Change Mode in Rotary Pumps Could Improve Pulsatility.
MedLine Citation:
PMID:  21615427     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Continuous-flow left ventricular assist devices (LVADs) have greatly improved the prognosis of patients with end-stage heart failure, even if continuous flow is different from physiological flow in that it has less pulsatility. A novel pump controller of continuous-flow LVADs has been developed, which can change its rotational speed (RS) in synchronization with the native cardiac cycle, and we speculated that pulsatile mode, which increases RS just in the systolic phase, can create more pulsatility than the current system with constant RS does. The purpose of the present study is to evaluate the effect of this pulsatile mode of continuous-flow LVADs on pulsatility in in vivo settings. Experiments were performed on eight adult goats (61.7 ± 7.5 kg). A centrifugal pump, EVAHEART (Sun Medical Technology Research Corporation, Nagano, Japan), was installed by the apex drainage and the descending aortic perfusion. A pacing lead for the detection of ventricular electrocardiogram was sutured on the anterior wall of the right ventricle. In the present study, we compared pulse pressure or other parameters in the following three conditions, including Circuit-Clamp (i.e., no pump support), Continuous mode (constant RS), and Pulsatile mode (increase RS in systole). Assist rate was calculated by dividing pump flow (PF) by the sum of PF and ascending aortic flow (AoF). In continuous and pulsatile modes, these assist rates were adjusted around 80-90%. The following three parameters were used to evaluate pulsatility, including pulse pressure, dp/dt of aortic pressure (AoP), and energy equivalent pulse pressure (EEP = (∫PF*AoP dt)/(∫PF dt), mm Hg). The percent difference between EEP and mean AoP is used as an indicator of pulsatility, and normally it is around 10% of mean AoP in physiological pulse. Both pulse pressure and mean dp/dt max were decreased in continuous mode compared with clamp condition, while those were regained by pulsatile mode nearly to clamp condition (pulse pressure, clamp/continuous/pulsatile, 25.0 ± 7.6/11.7 ± 6.4/22.6 ±  9.8 mm Hg, mean dp/dt max, 481.9 ± 207.6/75.6 ± 36.2/351.1 ± 137.8 mm Hg/s, respectively). In clamp condition, %EEP was 10% higher than mean AoP (P = 0.0078), while in continuous mode, %EEP was nearly equivalent to mean AoP (N.S.). In pulsatile mode, %EEP was 9% higher than mean AoP (P = 0.038). Our newly developed pulsatile mode of continuous-flow LVADs can produce pulsatility comparable to physiological pulsatile flow. Further investigation on the effect of this novel drive mode on organ perfusion is currently ongoing.
Authors:
Masahiko Ando; Takashi Nishimura; Yoshiaki Takewa; Kenji Yamazaki; Shunei Kyo; Minoru Ono; Tomonori Tsukiya; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi
Related Documents :
22196857 - Cerebrovascular time constant: dependence on cerebral perfusion pressure and end-tidal ...
18712357 - A biomechanical study of the meniscofemoral ligaments and their contribution to contact...
19002077 - Issls prize winner: microstructure and mechanical disruption of the lumbar disc annulus...
23585237 - Role of ambulatory blood pressure monitoring in resistant hypertension.
9152187 - Prediction of incontinence following low anterior resection for rectal carcinoma.
8809167 - Synthesis and selective coronary vasodilatory activity of 3,4-dihydro-2,2-bis(methoxyme...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-5-25
Journal Detail:
Title:  Artificial organs     Volume:  -     ISSN:  1525-1594     ISO Abbreviation:  -     Publication Date:  2011 May 
Date Detail:
Created Date:  2011-5-27     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Affiliation:
Department of Artificial Organ, National Cardiovascular Center Research Institute, Osaka; Department of Cardiothoracic Surgery, The University of Tokyo; Department of Therapeutic Strategy for Heart Failure, University of Tokyo Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The Efficacy of Disulfiram for the Treatment of Alcohol Use Disorder.
Next Document:  Exercise Capacity in Patients Supported With Rotary Blood Pumps Is Improved by a Spontaneous Increas...