Document Detail


Electrical Isolation of Both Left Pulmonary Veins by a Single Left Atrial Endocardial Radiofrequency Energy Application: Ablation of Marshall Bundle Bypass.
MedLine Citation:
PMID:  22469215     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The muscular sleeve contained within the ligament of Marshall (Marshall Bundle, MB) has been implicated in triggering and/or maintaining atrial fibrillation. Its connections may form a conduit between the left atrium (LA) and the left pulmonary veins (PVs) and challenge PV isolation attempts. In this case, radiofrequency (RF) ablation at antra of both left PVs failed to affect venous electrical activity. However, isolation of both PVs occurred simultaneously with a single, short (14 seconds) RF energy application at the mitral isthmus. This was delivered at a site recording a complex continuous electrogram (duration 100 ms), interpreted as the site of a single connection between LA and MB. (PACE 2012;e1-e5).
Authors:
Niraj Varma; Bernard Abi-Saleh
Related Documents :
22281385 - Postembolization perianeurysmal edema as a cause of uncinate seizures.
22778685 - Relative afferent pupillary defect: an unusual manifestation of carotid artery dissection.
6405105 - Complications of acute respiratory failure.
12151565 - Non-infectious pulmonary complications after bone marrow transplantation.
9294765 - Effects of balloon dilatation on eptfe structural characteristics.
7836675 - Intra-arterial papaverine for the treatment of cerebral vasospasm after subarachnoid he...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-1
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  -     ISSN:  1540-8159     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-3     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Affiliation:
Cleveland Clinic, Cleveland, Ohio.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  In Vitro Comparison of Fracture Strength of Experimental Hollow and Solid Design Zirconia Dowels.
Next Document:  Abstract Summaries of IANR IV and 8th GCNN Conference.