Electrical characteristics of an electronic control device under a physiologic load: a brief report.
MedLine Citation:
PMID:  20015134     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Law enforcement officers use electronic control devices (ECDs), such as the TASER X26 (TASER International, Inc., Scottsdale, AZ, USA), to control resisting subjects. Some of the debate on the safety of the devices has centered on the electrical characteristics of the devices. The electrical characteristics published by TASER International have historically based on discharges into a 400 Omega resistor. There are no studies that the authors are aware of that report the electrical characteristics under a physiologic load. In this study, we make an initial attempt to determine the electrical characteristics of the TASER X26 during a 5-second exposure in human volunteers. METHODS: Subjects received an exposure to the dry, bare chest (top probe), and abdomen (bottom probe) with a standard TASER X26 in the probe deployment mode for 5 seconds. There were 10-11 pulse captures during the 5 seconds. Resistance was calculated using the sum of the absolute values of the instantaneous voltage measurements divided by the sum of the absolute values of the instantaneous current measurements (Ohm's Law). RESULTS: For the eight subjects, the mean spread between top and bottom probes was 12.1 inches (30.7 cm). The mean resistance was 602.3 Omega, with a range of 470.5-691.4 Omega. The resistance decreased slightly over the 5-second discharge with a mean decrease of 8.0%. The mean rectified charge per pulse was 123.0 microC. The mean main phase charge per pulse was 110.5 microC. The mean pulse width was 126.9 micros. The mean voltage per pulse was 580.1 V. The mean current per pulse was 0.97 A. The average peak main phase voltage was 1899.2 V and the average peak main phase current was 3.10 A. Conclusions: The mean tissue resistance was 602.3 Omega in this study. There was a decrease in resistance of 8% over the 5-second exposure. This physiologic load is different than the 400 Omega laboratory load used historically by the manufacturer. We recommend future characterization of these devices use a physiologic load for reporting electrical characteristics. We also recommend that all the electrical characteristics be reported.
Authors:
Donald M Dawes; Jeffrey D Ho; Mark W Kroll; James R Miner
Related Documents :
17023354 - Electric polarization of polyelectrolyte and colloid media: dielectric versus electro-o...
11254344 - The electrophoretic mobility and electric conductivity of a concentrated suspension of ...
22540574 - Ratio m_{c}/m_{s} with wilson fermions.
8438154 - The secretory granule matrix: a fast-acting smart polymer.
12666774 - On using experimentally estimated wall shear stresses to validate numerically predicted...
21231224 - Coupled-channel calculation of nonelastic cross sections using a density-functional str...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2009-12-10
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  33     ISSN:  1540-8159     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  2010 Mar 
Date Detail:
Created Date:  2010-05-06     Completed Date:  2010-08-13     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  330-6     Citation Subset:  IM    
Affiliation:
Lompoc Valley Medical Center, Lompoc, California, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Electric Injuries / etiology
Electroshock / instrumentation*
Equipment Failure
Equipment Safety*
Female
Humans
Law Enforcement / methods*
Male
Middle Aged
Prospective Studies

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Successful Catheter Ablation of Reentrant Junctional Tachycardia in a Patient with Asplenia Syndrome...
Next Document:  Differential Manifestation of Cardiovascular Complaints as a Function of Utilization of Ergogenic Su...