Effects of direct mechanical ventricular assistance on regional myocardial function in an animal model of acute heart failure.
MedLine Citation:
PMID:  12662213     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Direct mechanical ventricular assistance (DMVA) improves hemodynamics in failing hearts without complications associated with a blood/device interface. Epicardial Doppler displacement transducers provide exact measurements of tissue displacement and regional myocardial function (RMF). An in vivo porcine model of acute heart failure was used to examine the effects of DMVA on RMF, which have not been reported before. In 8 anesthetized pigs cardiac output (CO), left ventricular pressure (LVP), aortic blood pressure (BP), systolic contractility (dp/dt max), and systolic wall thickening fraction (WT%) were measured. A multichamber pump system (IMPS) surrounding the left ventricle was implanted and the measurements were repeated. Then acute heart failure was induced by beta-blockade, resulting in a decline of all measured parameters to more than 30% compared to baseline values. In the further course of the experiment, repeated measurements were taken at several intervals with and without DMVA by the implanted device. The IMPS implantation caused no significant hemodynamic changes. Under conditions of acute heart failure DMVA improved LVP (46 +/- 7 to 81 +/- 9 mm Hg), dp/dt max (532 +/- 207 to 744 +/- 361 mm Hg/s), CO (1.5 +/- 0.1 to 1.9 +/- 0.5 L/min) and WT% (19 +/- 7% to 32 +/- 8%). Left ventricular myocardium not directly assisted by external pressure application showed improved regional myocardial function during DMVA. We conclude that DMVA is capable of improving hemodynamics due to extrinsic compression. It also enhances the remaining myocardial function of the failing heart, which might lead to myocardial recovery. These synergistic effects are considered responsible for the high efficiency shown by the IMPS in previous investigations.
Authors:
Ingo Kaczmarek; Peter Feindt; Udo Boeken; Semih Guerler; Emmeran Gams
Related Documents :
19095833 - Left ventricular assist device outflow cannula obstruction by the rare environmental fu...
16156313 - Left ventricular assist devices as bridge to heart transplantation in congestive heart ...
8504573 - One-year prognosis in patients hospitalized with a history of unstable angina pectoris.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Artificial organs     Volume:  27     ISSN:  0160-564X     ISO Abbreviation:  Artif Organs     Publication Date:  2003 Mar 
Date Detail:
Created Date:  2003-03-28     Completed Date:  2003-07-23     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  261-6     Citation Subset:  IM    
Affiliation:
Department of Thoracic and Cardiovascular Surgery, University Hospital, Heinrich-Heine University, Dusseldorf, Germany. dr4maus1@aol.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Acute Disease
Animals
Cardiac Output / physiology
Cardiac Output, Low / physiopathology*,  therapy*,  ultrasonography
Disease Models, Animal
Echocardiography, Doppler
Electrocardiography
Equipment Design
Heart / physiopathology*
Heart-Assist Devices*
Hemodynamics / physiology
Myocardial Contraction / physiology
Swine
Transducers, Pressure
Ventricular Dysfunction, Left / physiopathology*,  therapy*,  ultrasonography

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Inflammatory response of rat and human neutrophils exposed to di-(2-ethyl-hexyl)-phthalate-plasticiz...
Next Document:  An alternative design of locked percutaneous device for skeletal extension through skin.