OBJECTIVE: The purpose of this article is to assess whether iopamidol-370 provides superior vascular contrast of the coronaries and depiction of anatomic detail without affecting heart rate and beat-to-beat variability during coronary dual-source MDCT compared with iodixanol-320.
SUBJECTS AND METHODS: In this prospective trial, coronary CT angiography was performed on 60 adult patients using either iopamidol-370 or iodixanol-320. Cohorts were matched by age, habitus, sex, and baseline heart rate, with cohort sizes determined by power analysis. All studies were performed on a dual-source MDCT scanner with retrospective ECG-gating utilizing automatic pitch adjustment. Data assessment focused on heart rate variability during contrast administration statistically evaluated as Student t test comparisons within and between cohorts, coronary contrast-to-noise ratio analysis of the main coronary arteries utilizing Student t test comparisons between cohorts, and coronary branch depiction and distribution analysis in dual-reader consensus decisions between cohorts.
RESULTS: Thirty patients matched for age, habitus, sex, and heart rate were evaluated in each cohort. ECG analyses found a statistically significant (p = 0.013) decrease in heart rate during administration of iodixanol-320. Beat-to-beat variations, expressed as coefficient of variation, within and among cohorts were low (coefficient of variation, < 0.05). Contrast-to-noise ratio was significantly increased for iopamidol-370 versus iodixanol-320 (aortic root, p = 0.021; left main, p = 0.032; left anterior descending, p = 0.033; left circumflex, p = 0.039; and right, p = 0.009). Analysis of coronary branch visualization revealed improved depiction for iopamidol-370 compared with iodixanol-320.
CONCLUSION: Iopamidol-370, with its higher iodine concentration, provided greater vascular contrast of the arterial coronary tree and improved depiction of anatomic detail without significantly impacting cardiac heart rate during coronary MDCT imaging, as compared with iodixanol-320.
Authors:
Jared D Christensen; Laura T Meyer; Lynne M Hurwitz; Daniel T Boll
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  AJR. American journal of roentgenology     Volume:  197     ISSN:  1546-3141     ISO Abbreviation:  AJR Am J Roentgenol     Publication Date:  2011 Sep 
Date Detail:
Created Date:  2011-08-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7708173     Medline TA:  AJR Am J Roentgenol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  W445-51     Citation Subset:  AIM; IM    
Affiliation:
Department of Radiology, Duke University Medical Center, Erwin Rd, Box 3808, Durham, NC 27710.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  New and improved orthopedic hardware for the 21st century: part 2, lower extremity and axial skeleto...
Next Document:  Thoracic manifestations of inflammatory bowel disease.