Document Detail


Effect of tissue heterogeneity on an in vivo range verification technique for proton therapy.
MedLine Citation:
PMID:  22864304     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
It was proposed recently that time-resolved dose measurements during proton therapy treatment by passively scattered beams may be used for in vivo range verification. The method was shown to work accurately in a water tank. In this paper, we further evaluated the potential of the method for more clinically relevant situations where proton beams must pass through regions with significant tissue heterogeneities. Specifically, we considered prostate treatment where the use of anterior or anterior- oblique fields was recently proposed in order to reduce rectal dose by taking advantage of the sharp distal fall-off of the Bragg peak. These beam portals pass through various parts of pubic bone and potential air cavities in the bladder and bowels. Using blocks of materials with densities equivalent to bone, air, etc, arranged in the water tank in relevant configurations, we tested the robustness of the method against range shifting and range mixing. In the former, the beam range is changed uniformly by changes in tissue density in the beam path, while in the latter, variations in tissue heterogeneities across the beam cross section causes the mixing of beam energies downstream, as often occurs when the beam travels along the interface of materials with significantly different densities. We demonstrated that in the region of interest, the method can measure water-equivalent path length with accuracy better than ±0.5 mm for pure range shifting and still reasonable accuracy for range mixing between close beam energies. In situations with range mixing between significantly different beam energies, the dose rate profiles may be simulated for verifying the beam range. We also found that the above performances can be obtained with very small amount of dose (<0.5 cGy), if silicon diodes are used as detectors. This makes the method suitable for in vivo range verification prior to each treatment delivery.
Authors:
El Hassane Bentefour; Tang Shikui; Damien Prieels; Hsiao-Ming Lu
Related Documents :
22756354 - Su-e-t-174: synopsis of the experimental and monte carlo calculated values of the radia...
22297324 - Beyond gaussians: a study of single-spot modeling for scanning proton dose calculation.
22756214 - Su-e-t-33: prediction of exit dose images using xvmc and beamnrc monte carlo code.
22262814 - Predicting oscillatory dynamics in the movement of territorial animals.
15525024 - Importance of the internal shape mode in magnetic vortex dynamics.
20134844 - Evaluation of large aberrations using a lateral-shear interferometer having variable sh...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-8-03
Journal Detail:
Title:  Physics in medicine and biology     Volume:  57     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-8-6     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  5473-5484     Citation Subset:  -    
Affiliation:
Ion Beam Applications, S.A., 3 Chemin du Cyclotron, 1348 Louvain La Neuve, Belgium.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dose findings of antofloxacin hydrochloride for treating bacterial infections in an early clinical t...
Next Document:  Are valence and social avoidance associated with the memory conformity effect?