Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve.
MedLine Citation:
PMID:  18204312     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The cavitation intensity of a mechanical heart valve (MHV) may differ according to the geometry of the blood pump and driving mechanism. Our group is currently developing a pneumatic ventricular assist device (VAD), and the effects of different operating conditions on MHV cavitation in our pneumatic VAD were investigated. Tests were conducted under physiological pressure at heart rates ranging from 60 to 90 beats/min and at a systolic duration ranging from 38% to 43%. The valve-closing velocity was measured using a charge-coupled device (CCD) laser displacement sensor, and images of MHV cavitation were recorded using a high-speed video camera. A miniature pressure sensor was mounted 10 mm away from the inlet valve surface. The data were stored at a 1-MHz sampling rate using a digital oscilloscope. The pressure signal was band-pass filtered between 35 and 200 kHz using a digital filter. The cavitation bubbles were concentrated at the inlet valve stop, and were caused mainly by the squeeze flow. The band-pass filtered root mean squared (RMS) pressure and cavitation cycle duration increased with the closing velocity of the inlet valve. At a low heart rate and low systolic duration, the inlet valve closed before the outlet valve opened, which caused no cavitation bubbles to form around the valve stop.
Authors:
Hwansung Lee; Eisuke Tatsumi; Yoshiyuki Taenaka
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  54     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:    2008 Jan-Feb
Date Detail:
Created Date:  2008-01-21     Completed Date:  2008-06-18     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  25-30     Citation Subset:  IM    
Affiliation:
Department of Artificial Organs, Research Institute, National Cardiovascular Center, Osaka, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Biomechanics
Equipment Design
Heart Rate
Heart Valve Prosthesis*
Heart Valves / pathology
Heart, Artificial*
Heart-Assist Devices*
Humans
Materials Testing
Pressure
Prosthesis Design
Pulsatile Flow
Systole*
Time Factors
Video Recording

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Acute in vivo evaluation of an implantable continuous flow biventricular assist system.
Next Document:  Development of the DexAide right ventricular assist device inflow cannula.