Effect of subtalar arthroereisis on the tibiotalar contact characteristics in a cadaveric flatfoot model.
MedLine Citation:
PMID:  22608168     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Previous studies reported the effect of flatfoot deformity on tibiotalar joint contact characteristics. The lateral shift of the load which occurred in flatfeet may be responsible for degenerative changes in the ankle joint. The purpose was to assess the pattern of joint contact stress of the tibiotalar joint in intact, flat, and corrected specimens with subtalar arthroereisis. Seven fresh-frozen cadaver specimens were studied in the intact and flat-footed condition after transection of ligaments which support the medial arch. Ankle joint contact stress and plantar pressure patterns were determined from a capacitive pressure sensor inserted in the tibiotalar joint and a pressure distribution platform when the specimens were axially loaded in simulated mid-stance. Contact pressure was also assessed after subtalar arthroereisis with a 12mm Kalix implant for correction of the flatfoot deformity. A maximum contact pressure of 1414.2±319.2 kPa was recorded in the middle-medial region in intact specimens. Flatfoot caused a lateral shift in the pressure distribution (p<0.05). In the flat specimens, the maximum contact pressure of 1394.7 8±470.5kPa was in the anterior-central region. After subtalar arthroereisis with the Kalix implant for correction of the flatfoot deformity a maximum contact pressure of 1323.3±497.5kPa was observed in the middle-lateral region. In a cadaver model, subtalar arthroereisis with Kalix implant failed to restore a normal intraarticular ankle joint pressure pattern. Further interventions should be considered to restore a normal pressure pattern.
Authors:
N Martinelli; A Marinozzi; M Schulze; V Denaro; J Evers; A Bianchi; D Rosenbaum
Related Documents :
24031108 - Cardiovascular responses during head-down crooked kneeling position assumed in muslim p...
1578538 - The correlation between three methods of skin perfusion pressure measurement: radionucl...
10898528 - The effect of heptanol on the electrical and contractile function of the isolated, perf...
3656788 - Vascular responsiveness of isolated and perfused simian metacarpal veins to several vas...
20381318 - Serial measurements of high sensitive cardiac troponin i in patients with acutely decom...
9655788 - Hysteresis of the nasal pressure-flow relationship during hyperpnea in normal subjects.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of biomechanics     Volume:  45     ISSN:  1873-2380     ISO Abbreviation:  J Biomech     Publication Date:  2012 Jun 
Date Detail:
Created Date:  2012-05-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0157375     Medline TA:  J Biomech     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1745-8     Citation Subset:  IM    
Copyright Information:
Copyright © 2011 Elsevier Ltd. All rights reserved.
Affiliation:
Department of Foot and Ankle Surgery, Galeazzi Hospital, via R. Galeazzi, 20145 Milan, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Influence of pH and carbon to nitrogen ratio on mycotoxin production by Alternaria alternata in subm...
Next Document:  Analysis of the air/water channels of gastrointestinal endoscopies as a risk factor for the transmis...