Document Detail


Effect of shock polarity on defibrillation thresholds with a hybrid patch-coil lead system.
MedLine Citation:
PMID:  14618062     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
INTRODUCTION: Understanding the factors that affect defibrillation thresholds (DFTs) has important implications both for optimization of defibrillation efficacy and for the design of new lead systems. The objective of this prospective study was to evaluate the effect of shock polarity on defibrillation efficacy at the time of routine pulse generator replacement in patients with a hybrid patch-coil lead system. METHODS: Each patient underwent 4 assessments of DFT: monophasic or biphasic shock with standard or reversed polarity, with the order of testing with respect to polarity randomized. In standard polarity, the right atrial coil is the anode and the left ventricular patch is the cathode. RESULTS: The study population of 30 patients was 80% men with a mean age of 65 +/- 9 years and a mean left ventricular ejection fraction of 33 +/- 12%. There was a significant 21% decrease in the mean monophasic DFT with reversed polarity shocks (13.1 +/- 5.9 J vs. 16.6 +/- 6.5 J, p < 0.01). Reversal of shock polarity did not have a significant effect on the mean biphasic DFT (8.0 +/- 4.8 J vs. 8.5 +/- 4.3 J for reversed and standard polarity respectively, p = NS). However, when an elevated biphasic DFT (>or=15 J) was present in either standard or reversed polarity, a significant decrease in DFT was observed when the opposite polarity was used (16.7 +/- 2.5 J vs. 9.1 +/- 2.7 J, n = 9, p < 0.0001). CONCLUSION: Reversal of shock polarity markedly improves monophasic DFTs with the patch-coil lead configuration. The DFT should be determined with both shock polarities to optimize defibrillation efficacy for patients with high biphasic DFTs (>or=15 J).
Authors:
Eric J Rashba; Stephen R Shorofsky; Robert W Peters; Michael R Gold
Publication Detail:
Type:  Clinical Trial; Journal Article; Randomized Controlled Trial    
Journal Detail:
Title:  Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing     Volume:  9     ISSN:  1383-875X     ISO Abbreviation:  J Interv Card Electrophysiol     Publication Date:  2003 Dec 
Date Detail:
Created Date:  2003-11-17     Completed Date:  2004-04-23     Revised Date:  2006-09-18    
Medline Journal Info:
Nlm Unique ID:  9708966     Medline TA:  J Interv Card Electrophysiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  391-6     Citation Subset:  IM    
Affiliation:
Division of Cardiology, University of Maryland School of Medicine, Baltimore, MD 21201-1595, USA. erashba@medicine.umaryland.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Defibrillators, Implantable*
Differential Threshold
Electric Countershock* / methods*
Electrodes, Implanted
Female
Humans
Male
Middle Aged
Prospective Studies
Tachycardia / therapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prevention of sustained ventricular tachyarrhythmias in patients with implantable cardioverter-defib...
Next Document:  Ventricular rate stabilization algorithm of ICD causing dual chamber pacing during ventricular tachy...