Document Detail


Effect of light polymerization time, mode, and thermal and mechanical load cycling on microleakage in resin composite restorations.
MedLine Citation:
PMID:  23314786     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
This study evaluated the effect of polymerization mode and time and thermal and mechanical loading cycling (TMC) on microleakage in composite resin restorations. One hundred and eighty cavities were prepared and randomly divided according to the light curing time (20, 40, or 60 s), modes (quartz-tungsten-halogen (QTH)-420 mW/cm(2), LED 2 (2nd degree generation)-1,100 mW/cm(2), or LED 3 (3rd degree generation)-700 mW/cm(2)), and TMC. Following standard restorative procedures, the samples were prepared for analysis in an absorbance spectrophotometer. All results were statistically analyzed using the three-way ANOVA and Tukey test (p ≤ 0.05). The results revealed that the groups QTH and LED 3 submitted to TMC showed higher microleakage than those that were not submitted to TMC. Only for LED 3, 60 s showed higher microleakage than 20 s. For LED 2 and QTH, there were no differences between the times. QTH showed lower microleakage means than LED 2, when photoactivated for 20 s, without TMC. When photoactivated for 60 s, QTH showed lower microleakage means than LED 3, for the groups with or without TMC. It was concluded that TMC, the increase in polymerization time, and the irradiance were factors that may increase the marginal microleakage of class II cavities.
Authors:
Giulliana Panfiglio Soares; Glaucia Maria Bovi Ambrosano; Debora Alves Nunes Leite Lima; Giselle Maria Marchi; Lourenço Correr-Sobrinho; José Roberto Lovadino; Flávio Henrique Baggio Aguiar
Related Documents :
23878826 - Apical and root canal space sealing abilities of resin and glass ionomer-based root can...
24844416 - Bi-functionalization of a calcium phosphate-coated titanium surface with slow-release s...
17621236 - Coronal plane stability before and after total knee arthroplasty.
20360516 - Glenohumeral contact kinematics in patients after total shoulder arthroplasty.
17325596 - An improved equation for correcting slope-intercept measurements of glomerular filtrati...
24786136 - Accuracy of peri-implant bone evaluation using cone-beam computed tomography, digital i...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-13
Journal Detail:
Title:  Lasers in medical science     Volume:  -     ISSN:  1435-604X     ISO Abbreviation:  Lasers Med Sci     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611515     Medline TA:  Lasers Med Sci     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Restorative Dentistry, Piracicaba Dental School-University of Campinas, Av. Limeira, 901, Piracicaba, São Paulo, Brazil, 13414-903.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Tough nuts to crack: site-directed mutagenesis of bifidobacteria remains a challenge.
Next Document:  1-alpha,25-Dihydroxyvitamin-D3-3-Bromoacetate Regulates AKT/mTOR Signaling Cascades: A Previously Un...