Document Detail


Effect of light-enhanced bleaching on in vitro surface and intrapulpal temperature rise.
MedLine Citation:
PMID:  11778856     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: This study investigated the effect of the presence, absence, and aging of a heat-enhancing compound (colorant) added to bleaching gel on the temperature rise of the gel itself, as well as the temperature rise within the pulp chamber, when a tooth was exposed to a variety of light-curing units in vitro. MATERIALS AND METHODS: An extracted human upper central incisor was fitted with thermocouples placed in the pulp chamber as well as on the facial tooth surface. A temperature-controlled simulated intrapulpal fluid flow was provided to the tooth, and bleaching agent (Opalesence XTRA, Ultradent) containing heat-enhancing colorant, aged colorant, or no colorant was applied to the facial surface. The tooth and light-curing unit were placed in a thermostatically controlled oven at 37 degrees C, and real-time gel and intrapulpal temperature values were recorded digitally. Light-curing units used were a plasma arc light (PAC) (PowerPac, ADT), a conventional quartz tungsten halogen source (QTH) (Optilux 501, Demetron/Kerr), the QTH light used in high-power (bleaching) mode, and an argon ion laser (AccuCure 3000, LaserMed). An exposure scenario simulating light-enhanced bleaching of 10 upper teeth was developed. Temperature rise over the pre-exposure, baseline value associated with the last light exposure in the bleaching sequence was calculated for each curing and bleaching combination. Five replications for each test condition were made. Temperature rise values were compared using analysis of variance (ANOVA) at a preset alpha of 0.05. RESULTS: When fresh colorant-containing bleach was used, the PAC light increased bleach temperature 39.3 degrees C above baseline. With no added colorant, temperature rise was 37.1 degrees C. The QTH light in bleach mode resulted in gel temperature 24.8 degrees C above baseline, whereas the temperature increase was only 11.5 degrees C when no colorant was used. Conventional QTH light use increased fresh bleach temperature by 17.7 degrees C, whereas an increase of only 11.1 degrees C was measured without colorant. The argon ion laser produced equivalent temperature rise regardless of the presence or freshness of the colorant, approximately 9.4 degrees C. Intrapulpal temperatures were all significantly lower than those recorded in the bleaching gel and ranged from 5 degrees to 8 degrees C. As a rule, the presence of fresh heat-enhancing colorant in the bleaching gel resulted in a significant intrapulpal temperature increase (approximately 1 degrees C) over that reached using other lights. The PAC and the QTH light used in bleach mode induced greater intrapulpal temperature rise than the laser. CLINICAL SIGNIFICANCE: Freshness of bleaching agent incorporating light-activated, heat-enhancing colorant influences temperature rise of bleaching gel and also may increase intrapulpal temperature values. Use of intense lights does elevate bleach temperature and also results in increased intrapulpal temperature that may further impact on patient sensitivity and pulpal health resulting from this treatment.
Authors:
J W Baik; F A Rueggeberg; F R Liewehr
Related Documents :
18197756 - Dark nests and conspicuousness in color patterns of nestlings of altricial birds.
12660356 - Identification of cerebral networks by classification of the shape of bold responses.
9168596 - Role of remote adaptation in perceived subjective color.
19013216 - Poke and pop: tactile-visual synchrony increases visual saliency.
12729976 - Temporal discrimination in a long operant chamber.
17695986 - Biomechanical analysis of stress distribution in the temporomandibular joint.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]     Volume:  13     ISSN:  1496-4155     ISO Abbreviation:  J Esthet Restor Dent     Publication Date:  2001  
Date Detail:
Created Date:  2002-01-07     Completed Date:  2002-04-02     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  101096515     Medline TA:  J Esthet Restor Dent     Country:  Canada    
Other Details:
Languages:  eng     Pagination:  370-8     Citation Subset:  D    
Affiliation:
Endodontic Program, Fort Gordon, Georgia, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Analysis of Variance
Body Temperature
Color
Dental Pulp / physiology
Drug Combinations
Hot Temperature
Humans
Incisor
Infrared Rays
Lasers
Light
Peroxides / chemistry*,  radiation effects*
Statistics, Nonparametric
Tooth Bleaching / methods*
Ultraviolet Rays
Urea / analogs & derivatives*,  chemistry*,  radiation effects*
Chemical
Reg. No./Substance:
0/Drug Combinations; 0/Peroxides; 124-43-6/carbamide peroxide; 57-13-6/Urea

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Nightguard vital bleaching: a long-term study on efficacy, shade retention. side effects, and patien...
Next Document:  Tensile bond strengths of fourth- and fifth-generation dentin adhesives with packable resin composit...