Document Detail


Effect of force tightening on cable tension and displacement in greater trochanter reattachment.
MedLine Citation:
PMID:  22255646     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The purpose of this study was to evaluate cable tension during installation, and during loading similar to walking in a cable grip type greater trochanter (GT), reattachment system. A 4th generation Sawbones composite femur with osteotomised GT was reattached with four Cable-Ready® systems (Zimmer, Warsaw, IN). Cables were tightened at 3 different target installation forces (178, 356 and 534 N) and retightened once as recommended by the manufacturer. Cables tension was continuously monitored using in-situ load cells. To simulate walking, a custom frame was used to apply quasi static load on the head of a femoral stem implant (2340 N) and abductor pull (667 N) on the GT. GT displacement (gap and sliding) relative to the femur was measured using a 3D camera system. During installation, a drop in cable tension was observed when tightening subsequent cables: an average 40+12.2% and 11±5.9% tension loss was measured in the first and second cable. Therefore, retightening the cables, as recommended by the manufacturer, is important. During simulated walking, the second cable additionally lost up to 12.2+3.6% of tension. No difference was observed between the GT-femur gaps measured with cables tightened at different installation forces (p=0.32). The GT sliding however was significantly greater (0.9±0.3 mm) when target installation force was set to only 178 N compared to 356 N (0.2±0.1 mm); p<0.001. There were no significant changes when initial tightening force was increased to 534 N (0.3±0.1 mm); p=0.11. In conclusion, the cable tightening force should be as close as possible to that recommended by the manufacturer, because reducing it compromises the stability of the GT fragment, whereas increasing it does not improve this stability, but could lead to cable breakage.
Authors:
Fanny Canet; Kajsa Duke; Yan Bourgeois; G-Yves Laflamme; Vladimir Brailovski; Yvan Petit
Related Documents :
12006496 - Pif4, a phytochrome-interacting bhlh factor, functions as a negative regulator of phyto...
18184646 - Using virtual plants to analyse the light-foraging efficiency of a low-density cotton c...
16667106 - Blue-light regulation of specific transcript levels in pisum sativum: fluence-response,...
2485096 - Blue-light mediated accumulation of nuclear-encoded transcripts coding for proteins of ...
18782656 - Aromatase inhibitor-induced joint pain: melatonin's role.
21354576 - Minimum toe clearance adaptations to floor surface irregularity and gait speed.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference     Volume:  2011     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2012-01-18     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  5749-52     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Measurement of bulk mechanical properties of tissue using laser speckle rheology.
Next Document:  Modeling the internal pressure dependence of thermal conductivity and in vitro temperature measureme...