Document Detail


Effect of a contact monitoring system with immediate visual feedback on hand hygiene compliance.
MedLine Citation:
PMID:  25115494     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Hand hygiene compliance is traditionally monitored by visual methods that are open to bias and strictly limited in time and place. Automatic monitoring may be more effective for infection control as well as performance management.
AIM: To establish accuracy and acceptability of an automatic contact monitoring system for hand hygiene.
METHODS: Monitoring equipment was installed across 55 beds in three wards, and included modified identity badges, bedside furniture, sinks and alcohol gel dispensers. Badges were in near-skin contact (through uniform) and could detect alcohol vapour. All devices were linked by wi-fi. A traffic light system on the badge provided immediate feedback to staff and patients on the hand hygiene status of a member of staff on approach to a patient. Compliance was logged automatically. Following a period of immediate feedback, no visual feedback was given for two weeks. Subsequently, feedback was given using red/green lights for 10 days, followed by retrospective feedback to the ward. Hand hygiene was verified independently by an observer.
FINDINGS: Hand hygiene compliance increased from 21% of 97 opportunities to 66% of 197 opportunities during active immediate feedback. Compliance decreased when feedback was provided to wards retrospectively. Six staff (26%) avoided wearing a badge, saying that it was too heavy or they were not on the ward all day. Only three of 30 patients stated that they would challenge staff who had not performed hand hygiene.
CONCLUSIONS: Automatic contact monitoring with immediate feedback was effective in increasing hand hygiene compliance, but feedback given retrospectively did not prevent a decrease in compliance.
Authors:
S J Storey; G FitzGerald; G Moore; E Knights; S Atkinson; S Smith; O Freeman; P Cryer; A P R Wilson
Related Documents :
5696214 - Light-induced changes in the fluorescence yield of chlorophyll a in vivo. ii. chlorella...
19485494 - A versatile fiber-optic coupled system for sensitive optical spectroscopy in strong amb...
22652294 - Toward a more informative voice range profile: the role of laryngeal vibratory mechanis...
22480754 - Effects of vocal intensity and vowel type on cepstral analysis of voice.
9547804 - Influences of the accommodative stimulus and aging on the accommodative microfluctuations.
15760354 - Maternal effects provide phenotypic adaptation to local environmental conditions.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-7-24
Journal Detail:
Title:  The Journal of hospital infection     Volume:  -     ISSN:  1532-2939     ISO Abbreviation:  J. Hosp. Infect.     Publication Date:  2014 Jul 
Date Detail:
Created Date:  2014-8-13     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8007166     Medline TA:  J Hosp Infect     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cross-immunity and age patterns of influenza A(H5N1) infection.
Next Document:  Urinoma following Kidney Biopsy: A Case Report.