Abstract/OtherAbstract:
STUDY OBJECTIVE: Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical setups. The aim of this study was to investigate the effect of measurement site on PVP and its agreement with CVP in patients undergoing general anesthesia. DESIGN: Prospective randomized study. SETTINGS: University hospital. PATIENTS: Thirty patients of American Society of Anesthesiologists physical status I and II undergoing elective craniotomy. INTERVENTIONS: Patients were randomly assigned into Group A (antecubital; n=15) and Group D (dorsum hand; n=15) for antecubital and hand dorsum catheterization sites, respectively. Central venous pressure and PVP were monitored throughout the study. A total of 1925 simultaneous measurements were recorded at 5-minute intervals. Bland-Altman assessment for agreement was used for CVP and PVP in 2 groups. MEASUREMENTS: Peripheral venous pressure measurements were within the range of +/-2 mm Hg of CVP values, in 93.9% of the measurements in Group A, and in 91.2% of the measurements in Group D. Considering all measurements, mean bias was -0.072 mm Hg (95% CI, -0.134 to -0.010). Group A measurements showed a bias (CVP-PVP) of 0.173+/-3.557 mm Hg, whereas the bias was -0.122+/-4.322 mm Hg (mean+/-SDcorrected for repeated measurements) in Group D. All of the measurements were within mean+/-2SD of bias, which means that PVP and CVP are interchangeable in our clinical setting. CONCLUSION: Peripheral venous pressure measurement may be a noninvasive alternative for estimating CVP in patients undergoing elective neurosurgical operations. Measuring PVP from hand dorsum does not interfere with the agreement of CVP and PVP.
Authors:
Altan Sahin; M Alper Salman; A Ebru Salman; Ulku Aypar
Related Documents :
3625854 - Quantitation of corporeal venous outflow resistance in man by corporeal pressure flow e...
6742154 - A new method for estimating skeletal muscle capillary pressure.
1812874 - Central venous pulsations associated with a falsely low oxygen saturation measured by p...
3677284 - The relationship between central venous pressure and pulmonary capillary wedge pressure...
16648184 - Evidence of impaired hypoxic vasodilation after intermediate-duration hypoxic exposure ...
9631984 - Caffeine abstinence augments the systolic blood pressure response to adenosine in humans.
Publication Detail:
Type:  Journal Article; Randomized Controlled Trial    
Journal Detail:
Title:  Journal of clinical anesthesia     Volume:  17     ISSN:  0952-8180     ISO Abbreviation:  J Clin Anesth     Publication Date:  2005 Aug 
Date Detail:
Created Date:  2005-08-16     Completed Date:  2005-12-12     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8812166     Medline TA:  J Clin Anesth     Country:  United States    
Other Details:
Languages:  eng     Pagination:  348-52     Citation Subset:  IM    
Affiliation:
Department of Anesthesiology, Hacettepe University Faculty of Medicine, Ankara 06100, Turkey. asahin@hacettepe.edu.tr
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Catheterization, Peripheral*
Central Venous Pressure*
Craniotomy
Female
Humans
Male
Middle Aged
Prospective Studies
Venous Pressure*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Propofol concentration requirement for laryngeal mask airway insertion was highest with the ProSeal,...
Next Document:  The effect of hemodynamic changes induced by propofol induction on cerebral oxygenation in young and...